OPERATION

StudioMax III All Models

Flashing Rate:

The unit recharges quickly, as indicated by the READY light on the control

panel. A quick series of flashes can be obtained within the limits of the

recharge time. Continuous rapid flashing, however, can overheat and

damage the flashtube and internal parts. The maximum recommended rate

of flashing depends upon the power level being used and the amount of

operation time. Use the following chart to serve as a guide for the

maximum rate to use in your situation.

Power Level

Operating Time

Sec. Between

Flashes.

Number of

Flashes.

Full

Continuous

15

Continuous

30 minutes

10

180

1 minutes

4

15

1/4

Continuous

10

Continuous

30 minutes

6

300

3 minutes

4

45

1/32

1.5

Continuous

Exposure Information:

The following charts give the BCPS output for various umbrellas and reflectors.

Coverage angle is given in degrees. Divide BCPSnumbers in half for 160 w-s

units.

Umbrella

32 inch

45 inch

60 inch

Coverage

120 degree

120 degree

120 degree

Full Power

1658

1683

1683

1/2

829

841

841

1/4

414

421

421

1/8

207

210

210

1/16

104

105

105

Reflectors

None

7 ½”

14”

16”

20”

24”

Coverage

360°

35°

40°

60°

65°

145°

Full

703

7534

5274

7032

4922

1266

1/2

352

3767

2637

3516

2461

633

1/4

176

1884

1318

1758

1230

316

1/8

88

942

659

879

615

158

1/16

44

471

330

439

308

79

1/32

22

235

165

220

154

39

GN@

ASA 100

35

115

96

110

93

47

Advertising