Operating instructions, Operating infrared back burner, Operating digital timer – Blue Rhino GBC976W User Manual

Page 11: Checking for leaks, Operating main burners, Operating sear burner, Operating side burner

Advertising
background image

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

For great recipes and tips, visit recipes.uniflame.com

page no.

11

Turning Off

1. Turn LP gas tank valve to “CLOSED”.
2. Turn control knob clockwise to the “OFF” position.
Note: A “poof” sound is normal as the last of the LP gas is burned.

Cooking

1. Open lid and ignite the burner per lighting instructions in owner’s manual.
2. Adjust controls to desired flame height.
3. Place pan on center of grid.
4. Cook and adjust temperature as needed.
5. Turn grill OFF by turning the LP gas tank valve to “CLOSED”. Burn off remaining gas in lines

by waiting 15 seconds then turn all burner controls to the “OFF” position. A “poof” sound is
normal as the last of the LP gas is burned.

Operating Infrared Back Burner

First Use

1. Make sure all labels, packaging and protective films have been removed from the grill.
2. Remove manufacturing oils before cooking on this grill for the first time, by operating the grill

for at least 15 minutes on “HIGH” with the lid closed. This will “heat clean” the internal parts
and dissipate odors.

Lighting

NOTE: Infrared back burner can be used while main burners are operating.
1. Open lid.

Attempting to light the burner with the lid closed may cause an explosion!

2. Make sure there are no obstructions of airflow to the burners. Spiders and insects can nest

within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a
fire beneath the appliance.

3. All control knobs must be in the “OFF” position. (Figure 3)
4. Turn LP gas tank valve to “OPEN”.
5. Push and turn control knob slowly about 1/4 turn counter clockwise until a click is heard. The

burner should light. If the burner does not light, repeat up to three times.

6. Hold the knob 3 to 5 seconds to allow gas to reach and light the burner.
7. Burner should turn red after 2 to 3 minutes.
8. Turn control knob “OFF” if burner is not lit. Wait 5 minutes and repeat lighting procedure.

Caution: If burner flame goes out during operation, immediately turn

the gas “OFF” and open lid to let the gas clear for about 5 minutes

before re-lighting.

Turning Off

1. Turn LP gas tank valve to “CLOSED”.
2. Turn all control knobs clockwise to the “OFF” position.

Operating Digital Timer

Count-Up

1. Press the ‘Start/Stop’ button. The timer will begin counting up from 0:00.
2. Press the ‘Start/Stop’ button. The timer will stop.

Count-Down

1. Press the ‘minute’ button to set the desired number

of minutes.

2. Press the ‘Seconds’ button to set the desired

number of seconds.

3. Press the ‘Start/Stop’ button. The timer will begin

counting down from the pre-set time.

4. When the timer reaches 0:00 a loud beep will sound

for up to 1 minute.

5. To stop the count-down at any time or stop the

alarm from sounding, press the ‘Start/Stop’ button.

Light

Press the ‘Light’ button and the LCD will illuminate for 10 seconds.
Resetting the timer
If you have stopped the timer during count-up or count-down mode, you can reset it back to
0:00 by pressing and holding the two buttons indicated by the ‘reset’ lines.

Auto Shut-off

In order to increase the battery life, the digital timer will automatically shut off when not in use
after 30 seconds. To turn it back on press the ‘Start/Stop’ button

Operating Instructions

Checking for Leaks

Burner Connections

1. Make sure the regulator valve and hose connections

are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.

WARNING: Failure to inspect this

connection or follow these instructions

could cause a fire or an explosion

which can cause death, serious bodily

injury, or damage to property.

2. Please refer to diagram for proper installation.

(Figure 1 and 2)

3. If the burner pipe does not rest flush to the orifice,

please contact 1.800.762.1142 for assistance.

Tank/Gas Line Connection

1. Make 2-3 oz. of leak solution by mixing one part

liquid dishwashing soap with three parts water.

2. Make sure control knobs are “OFF”. (Figure 3)
3. Turn LP gas tank valve to “OPEN”.
4. Spoon leak check solution at all “X” locations

(Figure 4)
a. If any bubbles appear turn LP gas tank valve to

“CLOSED”, reconnect and re-test.

b. If you continue to see bubbles after several

attempts, turn LP gas tank valve to “CLOSED”
and disconnect LP gas tank and contact
1.800.762.1142 for assistance.

c. If no bubbles appear after one minute turn LP gas

tank valve to “CLOSED”, wipe away solution and
proceed.

Operating Main Burners

First Use

1. Make sure all labels, packaging and protective films

have been removed from the grill.

2. Remove manufacturing oils before cooking on this

grill for the first time by operating the grill for at
least 15 minutes on “HIGH” with the lid closed. This
will “heat clean” the internal parts and dissipate
odors.

Lighting

1. Open lid.

Attempting to light the burner with the

lid closed may cause an explosion!

2. Make sure there are no obstructions of airflow to

the burners. Spiders and insects can nest within
and clog the burner / venturi tube at the orifice. A
clogged burner tube can lead to a fire beneath the
appliance.

3. All control knobs must be in the “OFF” position.

(Figure 3)

4. Turn LP gas tank valve to “OPEN”.
5. Push and turn control knob slowly about 1/4 turn

counter clockwise until a click is heard. The burner
should light. If the burner does not light, repeat up to
three times.

6. If ignition does not occur in 5 seconds, turn burner

control knob “OFF”, wait 5 minutes, and repeat
lighting procedure.

7. If igniter does not light burner, use a lit match

secured with the lighting rod provided to light
burners manually. Access the burners through the
cooking grid and heat plates. Position the lit match
near side of the burner. (Figure 5)

Important: Always use the lighting rod provided when
lighting burners with a match.
8. After lighting, observe the burner flame, make sure

all burner ports are lit and flame height matches
illustration. (Figure 6)

Note: Each burner lights independently - repeat steps
5-9 for the other burners.

Operating Sear Burner

First Use

1. Make sure all labels, packaging and protective films have been removed from the grill.
2. Remove manufacturing oils before cooking on this grill for the first time, by operating the grill

for at least 15 minutes on “HIGH” with the lid closed. This will “heat clean” the internal parts
and dissipate odors.

Lighting

NOTE: Infrared sear burner can be used while main burners are operating.
1. Open lid.

Attempting to light the burner with the lid closed may cause an explosion!

2. Make sure there are no obstructions of airflow to the burners. Spiders and insects can nest

within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a
fire beneath the appliance.

3. All control knobs must be in the “OFF” position. (Figure 3)
4. Turn LP gas tank valve to “OPEN”.
5. Push and turn control knob slowly about 1/4 turn counter clockwise until a click is heard. The

burner should light. If the burner does not light, repeat up to three times.

6. Hold the knob 3 to 5 seconds to allow gas to reach and light the burner.
7. Burner should turn red after 2 to 3 minutes.
8. Turn control knob “OFF” if burner is not lit. Wait 5 minutes and repeat lighting procedure.

Caution: If burner flame goes out during operation, immediately turn

the gas “OFF” and open lid to let the gas clear for about 5 minutes

before re-lighting.

Turning Off

1. Turn LP gas tank valve to “CLOSED”.
2. Turn all control knobs clockwise to the “OFF” position.

Cooking

Ideal for searing in juices and flavor in food, such as steaks, roasts, and chicken parts.
1. Open lid and ignite the burner per lighting instructions.
2. Close lid and preheat grill on “HIGH”.
3. Wear protective gloves and use long handle tongs to place food onto cooking grids above the

burner.

4. Adjust control to desired temperature.
5. Keep an eye on the food to make sure the food does not burn, as it will take a very short time

to sear each side of the food. Turn as desired.

6. Turn grill OFF by turning the LP gas tank valve to “CLOSED”. Burn off remaining gas in lines

by waiting 15 seconds then turn all burner controls to the “OFF” position. A “poof” sound is
normal as the last of the LP gas is burned.

Operating Side Burner

NOTE: Side burner can be used while main burners

are operating.
Never use side burner as a grill.

Lighting

1. Open lid.

Attempting to light the burner with the

lid closed may cause an explosion!

2. Make sure there are no obstructions of airflow to the

burner. Spiders and insects can nest within and clog
the burner / venturi tube at the orifice. A clogged
burner tube can lead to a fire beneath the appliance.

3. Control knob must be in the “OFF” position.

(Figure 7)

4. Turn LP gas tank valve to “OPEN”.
5. Push and turn control knob counterclockwise to

“HIGH”.

6. Press the electronic igniter button and hold for 5

seconds to light burner.

7. If ignition does not occur in 5 seconds, turn burner

control knob “OFF”, wait 5 minutes, and repeat
lighting procedure.

8. If igniter does not light burner, use a lit match

secured with the lighting rod provided to light
burners manually. Position the lit match near side of
the burner. (Figure 8)

Important: Always use the lighting rod provided when
lighting burners with a match.
9. After lighting, observe the burner flame, make sure

all burner ports are lit and flame height matches
illustration. (Figure 9)

CAUTION: If burner flame goes out

during operation, immediately turn

the gas “OFF” and open lid to let the

gas clear for about 5 minutes before

re-lighting.

Figure 7

Figure 8

Figure 9

Burner

Flame

Slight

Yellow

Slight

Blue

Dark

Blue

Figure 10

Digital Timer