Powers 450-e420 HydroPanel II Shower System - Extensions User Manual

Technical instructions, Hydropanel, Ii modular shrouding system

Advertising
background image

A

A

A

O

O

O

E

C

End Cap

End Cap

O

O

E

With the Powers Hydropanel II Modular Shrouding System
you can specify standardized shrouding panels to cover all
shower room piping, without the expense of customized
components. By using the Powers specification charts,
you coordinate different sizes of the five panel types,

based on the dimensions of your shower room. The modu-
lar components promote easy installation and fast delivery.
Hydropanel II Modular Shrouding is stainless steel and uti-
lizes vandal resistant fasteners with standardized heads.

TECHNICAL INSTRUCTIONS

HYDROPANEL

TM

II

MODULAR SHROUDING SYSTEM

Form TI 450SH v3

DESCRIPTION

1. The distance between the centerlines of two vertical

sections (vertical piping run or Hydropanel II unit)
should be at least 18

"

[460 mm]. Recommended stan-

dard distance is 36

"

[915 mm].

2. The distance between the centerline of any vertical sec-

tion (vertical piping run or Hydropanel II unit) and a wall
should be at least 20

"

[510 mm].

3. The distance between the top of a Hydropanel II unit

and the ceiling should be at least 9-1/2

"

[940 mm].

4. 16

"

[405 mm] Horizontal Adapters are used at the end of

a piping run.

5. Each Corner Adapter, 13

"

, 16

"

, 18

"

, 23

"

, or 28

"

Overlay,

or Extension Kit includes a stainless steel panel, and (2)
mounting brackets with (2) screws. Each Horizontal
Adapter or 8

"

Overlay Kit includes a stainless steel

panel and (4) mounting brackets with (4) screws (wall
mounting screws not provided).

6. The 16

"

Horizontal Adapter Kit includes an End Cap Kit.

The End Cap Kit comes complete with (1) chrome plat-
ed end cap and (3) mounting screws.

7. Position the brackets on the wall according to the

dimensions of the individual piece of shrouding (refer to
pages 3 and 4 for drawings). You can also hold the
piece of shrouding to the wall as a template to deter-
mine bracket position.

8. All brackets mount with the 1/4

"

hole to the wall, facing

in (refer to Figure 1).

9. The 3/4

"

wide oval mounting holes on the shrouding

allow up to 1/2

"

error in shroud/bracket mounting.

GUIDELINES

To install Hydropanel II Modular Shrouding, follow the
room layout drawing from Form #PS450SH. The product
specification diagram not only describes the positions of
the different types and sizes of shrouding, but also pro-
vides the following information:

• Room dimensions and showerhead height.
• The number of shower units in the plan.
• The beginning, end and changes in direction of the

supply piping.

• The walls on which to mount the corner shrouding.

On each shrouding component is a letter-number code
that represents panel type and length (as listed below).
Shrouding components install in the following general
order, in thefollowing situations:

1. Horizontal Adapters (A16, A24, A48)

a. Piping bends/ends-of-run.
b. Hydropanel II units.

2. Corner Adapters - going into the corner (C10)

Fit the Corner Adapter onto the appropriate wall.

3. Extensions (E6, E24)

a. Into the cutout on top of the Horizontal Adapters.
b.Vertically onto the top of a Hydropanel II unit.
c. Special cases: on an open end of an Adapter to

extend its reach.

4. Overlays (O8, O13, O18, O23, O28)

a. Between two Horizontal Adapters.
b. Between a Corner Adapter and Horizontal Adapter

on the same wall.

c. Between a Corner Adapter and Horizontal Adapter
on adjacent walls (90° angle).
d. Between the ceiling and an Extension.
e. Special cases: between an Extension and an
Adapter.

5. End Caps

Fit End Caps onto the open ends of Horizontal

Adapters or atop an open Hydropanel II unit.

GETTING READY

5"

1/4" DIA..

10-32 UNF-2B THD.

WALL

Figure 1. Mounting Brackets and Shrouding