Powers 450 Meter HydroPanel II Shower System with Metering Valve User Manual

Page 3

Advertising
background image

Set the Metering Cycle

The metering valve can cycle for up to one minute.

12.To adjust, insert the the 3/32” allen wrench into the small

hole in the center of the pushbutton (see Figure 5). Inside the
hole is the metering cycle timing needle.

13.To increase the shower time, turn the allen wrench counter-

clockwise. This will widen the distance inside the valve
between the timing needle and the valve seat.

14.To decrease the shower time, turn the allen wrench clock-

wise. This will shorten the distance inside the valve between
the timing needle and the valve seat.

Assemble the Valve Cover

15.(Figure 4) Secure the piping to the shroud with the two

screws at E.

16.(Figure 4) Slide faceplate over the valve and attach it to the

shroud with the 1” screws at D.

17.(Figure 4) Finish assembly by tightening the shrouding screw

at A above the showerhead.

Before servicing valve or piping, turn off the supply water
upstream or close the stop valve.

To access the stop valve, refer to Figure 5. Remove the two

faceplate screws, then slide the faceplate over the valve. A small
hole in the shrouding allows access to the stop valve. To close,
turn the adjustment screw fully clockwise. To open, turn the
adjustment screw fully counterclockwise.

The timing cartridge for the metering valve is replaceable as a
single cartridge. Every six months, check the timing on the valve
and inspect for sticking.

To service or clean the showerhead, unscrew from shroud at hex
nut. Service as necessary, and reattach.

TI450-M

Page 3

INSTALLATION, CONTINUED

SERVICING THE HYDROPANEL UNIT

*NOTE*: If problems with water tempering occur, please refer to
the appropriate technical instructions for your master mixing
valve.

1. If the flow of water is less than desired...

a. The upstream master mixer may not be fully open.*
c. The showerhead may be clogged. Remove and clean.
b. The metering cartridge may be sticking. Access and check.

Service with Repair Kit #141 839.

d. The stop valve may not be fully open. Access and adjust

accordingly.

2. If the flow of water is completely shut off...

a. The upstream master mixer may be shut-off.*
b. The metering valve may be stuck. Access and check.

Service with Repair Kit #141 839.

c. The stop valve may be closed. Access and open by turning

the adjustment screw fully counterclockwise.

3. If water continues to flow from the showerhead after

valve shut-off...

a. The metering valve may damaged. Access and check for

sticking. Service with Repair Kit #141 839.

4. If water continues to flow beyond desired cycle time...

a. The metering valve timing needle needs to be readjusted.

Refer to Setting the Metering Cycle.

TROUBLESHOOTING

Stop valve

PUSH

Timing Adjustment

- longer shower time - shorter shower time

Stop valve
access hole

Faceplate

screws

Figure 5.

Advertising