TO INSTALL

1. Remove “A” (Bonnet nut) and “B” (Bonnet assembly).

2. Remove old cartridge “C”.

3. Apply Silicone Grease to areas indicated by the arrows.

4. Place adapters onto back of cartridge.

5. Place “C” (Cartridge assembly) into valve body. Be careful

to align adapters with holes in the body.

6. Replace “B” (Bonnet assembly). Note that the word “TOP”

is stamped into the stem. Make sure the word “TOP” is
facing upward.

7. Replace “A” (Bonnet nut).

INSTALLATION INSTRUCTIONS