Powers e420 Series Combination T/P Tempering Valves - Cartridge (420-451) User Manual

Technical instructions

Advertising
background image

HydroGuard

®

T/P Series e420

Complete Retrofit

Technical Instructions

IS-P-420R

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use

information can result in death, serious

personal injury, property damage, or damage

to the equipment.
Keep this Manual for future reference.

WARNING

Need for Periodic Inspection/Maintenance: This product

must be tested periodically in compliance with local codes,

but at least once per year or more as service conditions

warrant. All products must be retested once maintenance

has been performed. Corrosive water conditions, inlet tem-

peratures over 200°F (93°C), and/or unauthorized adjustments

or repair could render the product ineffective for the service

intended. Regular checking and cleaning of the product’s

internal components helps assure maximum life and proper

product function.

WARNING

!

Before you begin your upgrade, take the time to ensure you have

all the necessary pieces. Your retrofit kit, for each valve, consists of

the following (refer to above diagram when taking inventory):
1. Cartridge Assembly (w/2 “O”-rings).
2. Wax Element.
3. Bonnet Assembly.
4. Spline Temperature Limit Stop (2 pieces).
5. Bonnet “O”-Ring.
6. Lubricant.
7. Four (4) Bonnet Screws.

After you verify that you have everything needed to complete the

retrofit, proceed with the next section.

Follow the instructions below to perform your retrofit. Save all com-

ponents until you have successfully completed your retrofit.

Retrofit

n

1. Turn off hot & cold water supply-stops (required for this retrofit).
2. Remove the handle and trim plate.
3. Remove 4 bonnet screws and bonnet assembly.
4. Remove all internal components from valve body.
5. Remove hot water seat using 7/8" hex socket.
6. At this point you should have an empty valve body.
You are now ready to put the new components into your existing

valve.

Disassembly

n

Figure 2

The following instructions explain how to retrofit your

existing 420 HydroGuard to the new, enhanced version which

utilizes a wax element and cartridge type design.

The combination of these design concepts results in a valve

with enhanced performance. See the exploded view of this new

assembly below:

420 Retrofit Instructions

n

Figure 1

420-451 KIT

Reassembly

n

1. Ensure the inside of the valve body is free of deposits and

debris. Clean as necessary.

2. Push the cartridge into the body without the “O” rings installed.

The cartridge should slide in easily, and bottom out with its large

Advertising