Powers LM490/LM490-10 Series Thermostatic Tempering Valves for Hot Water Heater & Multiple Lavatory Installations User Manual

Installation instructions, Quick-connect installation, Warning

Advertising
background image

HYDROGUARD

®

Thermostatic Tempering Valves

ASSE 1017 Series LFLM490 and LFLM490-10

Installation Instructions

IS-P-LM490-LM490-10

1. Mark pipe as shown.

This is pipe insertion depth.

2. Clean pipe end.

1. Remove collet clip.

2. Depress collet.
3. Pull tubing from tailpiece .

3. If using PEX tubing, insert pipe stiff-

ener (provided) into end of pipe.

4. Push tubing into tailpiece up to mark.
5. Insert collet clip.

PEX tubing only

Pipe Stiffener

Tail Piece

Mark

Collet clip

Collet depressed

1

1

/

2

in. (38.1mm)

1

3

/

4

in. (44.45mm)

1

7

/

8

in. (47.63mm)

1

/

2

in.Pipe (12.7mm)

3

/

4

in.Pipe (19.05mm)

1 in.Pipe (25.4mm)

LFLM490-5

LFLM490-1

Quick-Connect Installation

n

TO CONNECT

TO DISCONNECT

Advanced Thermal

Activation

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use infor-

mation can result in death, serious personal injury,

property damage, or damage to the equipment.
Keep this Manual for future reference.

You are required to consult the local building and plumbing

codes prior to installation. If the information in this manual

is not consistent with local building or plumbing codes,

the local codes should be followed. Inquire with governing

authorities for additional local requirements.

WARNING

!

WARNING

!

Need for Periodic Inspection and Yearly Maintenance:

Periodic inspection and yearly maintenance by a licensed

contractor is required. Corrosive water conditions, and/or

unauthorized adjustments or repair could render the valve

ineffective for service intended. Regular checking and

cleaning of the valve’s internal components and check

stops helps assure maximum life and proper product

function. Frequency of cleaning and inspection depends

upon local water conditions.

ATTENTION INSTALLER:

After installation, please leave this Instruction Sheet

for occupant’s information.

FAILURE TO COMPLY WITH PROPER INSTALLATION AND

MAINTENANCE INSTRUCTIONS COULD CONTRIBUTE TO THE

VALVE FAILURE.
This Hot Water Master Tempering Valves cannot be used for

tempering water temperature at fixtures. Severe bodily injury

(i.e., scalding or chilling) and/or death may result depending

upon system water pressure changes and/or supply water

temperature changes. ASSE standard 1016, 1069 or 1070 listed

devices should be used at fixtures to prevent possible injury.
These Hot Water Tempering Valves are designed to be

installed at or near the boiler or water heater. They are not

designed to compensate for system pressure fluctuations and

should not be used where ASSE standard 1016, 1069 or 1070

devices are required. These valves should never be used to

provide “anti-scald” or “anti-chill” service.
The components of the system must be of materials with a

construction capable of withstanding the high limit output tem-

peratures of the water heating source.

WARNING

!

Advertising