Troubleshooting – Bakers Pride Fry Warmer HFW User Manual

Page 13

Advertising
background image

BKI Fry Warmer

Maintenance

11

Troubleshooting

Refer to the table below for troubleshooting information.

Problem Cause

Possible

Solution

Package Holding Area is
not holding heat

Ceramic heating
element failure

Contact an authorized BKI service agent for
corrective action.

Noisy fan

Fan blade is dirty or fan
bearings are failing

Contact an authorized BKI service agent for
corrective action.

Package Holding Area is
not heating and perforated
pan is not heating

No power to unit.

Make sure that the circuit breaker and switch at the
power supply are supplying power to the unit. If
problem persists, contact licensed electrician.

Pilot light on Hood
Illuminated

Package Holding Area is
heating and the perforated
pan is not heating

Fan has overheated and
cut off

Or

Heating coil has failed

Wipe the dust from the air intake louvers to allow
proper airflow and prevent fan overheating. Also
check exhaust grid for blockage and clean if
necessary. Turn the power switch off. Wait 60
seconds. Turn the power switch back on.

Contact an authorized BKI service agent for
corrective action.