RCBS Ultrasonic Cleaner User Manual

Page 4

Advertising
background image

6

7

DISPLAY

1. Digital Timer Display - Displays the set run time.
2. Water Temperature Indicator - Solid green light indicates
that the water temperature is 0-30% of the set temperature. Solid orange light
indicates that the water temperature is 30-60% of the set temperature. Solid red
light indicates that the water temperature is 60-90% of the set temperature.
Flashing red light indicates that the water temperature is close to the set
temperature. All solid lights indicate that the water temperature is at the set
temperature (90-100%).
3. Set Temperature Display - Display will show one of the 5 pre-set temperatures.
40 104°F, 45 113°F, 50 122°F, 55 131°F and 60 140°F
4. Set Temperature Units Indicator - Indicates if temperature is either ºC or °F.
5. Solution Timer – Counts down to show remaining solution usage (Hour:Min).
6. Solution Set Indicator - When is flashing solution needs to be changed
and timer needs to be reset. When is displayed, solution timer is set and timer
will begin counting down when Ultrasonic Cleaner is in operation.
7. Degas Status - When is displayed, unit is in degassing mode.
8. heater Status – When is illuminated heater is turned on. If is not
illuminated, the heater is turned off.
9. Normal Cleaning Status – When is illuminated, normal cleaning is
underway.
10. Indicator Lights - Working status
Green – Ready: Green light indicates normal working status, ready to use.
Red – Overheat (R): Red light indicates overheat protection. 20 minutes or more time
required for the light to change from red to green. When light is green normal opera-
tion may resume.

kEYPAD

11. Function Button - Functions (Degas/Normal). Depressing function button
will illuminate, indicating degassing function is desired. Depressing function
button again will illuminate indicating normal ultrasonic cleaning. Pressing On/
Off button will begin cleaning. If unit is in degassing mode, will flash for 2 minutes
while unit is degassing. After 2 minutes has elapsed, will illuminate, indicating
normal ultrasonic cleaning has begun and degassing has stopped. If more
degassing is required depress function button and will illuminate indicating
degassing is underway.
12. Temp Button - Temperature set button. 5 pre-set temperatures can be se-
lected. Press Temp button to select the temperature in the following sequence:
40 104°F, 45 113°F, 50 122°F, 55 131°F and 60 140°F.
The temperatures are pre-set and will display temperature in ºC first then °F.
13. Time Button - Timer quick set button. Press Time button, LED will display
run time. When time button is depressed, time will increase by 5 minutes up to a
maximum run time of 30 minutes.
14. On/Off Button - On/off switch. When unit is plugged in and the unit is powered
on the LED will display, the default 05:00 minutes run time and the unit is ready
to operate in the normal ultrasonic cleaning mode for 5 minutes. Press the On/Off
button once to initiate cleaning. The cleaning will stop when the timer counts down
to 00:00. If the unit needs to be Stopped, before the timer runs out, press the On/Off
button to turn off ultrasonic cleaning.
15. h/min - Solution Timer Set Button. Each time is depressed; the timer is
increased by 20 min. The maximum time that can be set is 9 hr 60 min. When
flashes solution needs to be changed. Depressing button will reset timer.
16. Button - Decreasing Button.
When Time is used, each pressing reduces the timer by 1 minute. When Temp is
used, each pressing reduces the set temperature down to the next level. When h/min
is used, each pressing reduces the solution set time by 20 minutes.
17. heater Button — heater On/Off Button. Pressing Heater button will flash
indicating heater is turned on. To cancel heating, press Heater button again and
will dim, indicating heater has been turned off.
When water reaches the set temperature the heater will turn off automatically.

1

2

3
5
7
9

10

4
6
8

11

14

15

13

12

16

17

Advertising