Storage, Keypad layout, Functions – RCBS AmmoMaster Chronograph User Manual

Page 4: On/off

Advertising
background image

Figure 10 - Initialization Screen

4.  Once  the  Display  shows  a  shot  number  and  an  indicator  next  to 

“Ready”, the AmmoMaster

®

 unit is ready to record velocities (See 

Figure 11).

Figure 11 - “Ready” on Shot #1

5. Measure the distance between the bore of the weapon system and

the sighting system. Typically this distance is 1.5" on a rifle with an 

optical scope. Remember that your line of sight will be higher than

the path of the projectile. The ideal projectile path is centered over the

chronograph at a height of 4.0 inches above the top of the Skyscreen 

(See Figure 9). The projectile/ bullet height should be kept within ± 

1.5 inches of this location for accurate velocity measurements.

WARNING!  BE  CAREFUL  NOT  TO  AIM  ANY  LOWER  THAN 

THIS, AS IT MAY CAUSE SERIOUS DAMAGE TO THE

SKYSCREEN AND POTENTIALLY CAUSE SERIOUS INJURY TO

THE SHOOTER.

a.  We  recommend  using  a  bench,  sand  bags,  bi-pods,  or  other 

means to stabilize your weapon.

b. if you are concerned about hitting your chronograph, start by

removing your diffusers and Side Supports. place a paper target

immediately behind your chronograph and aim several inches

above the top surface of the Skyscreens. Work your shots lower

in small increments until your shot placement is in the correct

location. Make note of that aiming spot. if desired, place a piece of

tape on the Side Support as a visual reference for your aim point

of that particular firearm. Repeat this procedure for each weapon 

used in conjunction with your chronograph.

6.  Shoot a round at the correct aiming point as mentioned above, to 

start recording your velocity measurements.

ALWAYS WEAR EYE AND HEARING PROTECTION.

7.  Please  refer  to  the  detailed  instructions  listed  on  pages  5-8  

to become more familiar with the full functionality of the

AmmoMaster

®

Chronograph.

8. ENJOY.

STORAGE

Follow steps 1 – 7 of the “Assembly” section in reverse sequence. Your 

Chronograph should be stored in a dry, cool place away from direct

sunlight if possible. Although the plastic components of your unit are

manufactured with a uV inhibitor additive, limiting unnecessary uV

exposure of any plastic device is recommended. Do not leave your unit 

outside for long periods of time.

KEYPAD LAYOUT

BUTTON

FUNCTION

DESCRIPTION

power Button

Turn unit On. Turn unit Off, depress button and hold for 3-5 sec.

Change units

Depress to switch from f/s to m/s.

Scroll left

Scroll to the left (decreasing shot #) while in Stats Mode and 

edit String Mode

Scroll Right

Scroll to the right (increasing shot #) while in Stats Mode and 

edit String Mode

Adds data

to string

Add data to an existing shot string while in Edit String Mode

no command

depress no if choose not to delete velocity or string or clear all.

enter edit

String Mode

edit String Mode allows editing of recorded velocities in

selected shot strings.

delete data

in string

delete current velocity recorded; delete any recorded velocity

in any shot string.

yes command

depress yes if choose to delete velocity or string or clear all.

enter Stats

Mode

displays statistical data for a selected shot string.

Clear a

selected string Clear function will clear all data within a selected shot string.

delete all

recorded data

Reset will clear all recorded data in all shot strings.

Accept results

depress enter to select desired shot string, accepts the results

in the stats mode.

Starts new

shot string

Starts new shot string

FUNCTIONS

On/Off

 To turn unit on - depress “On/Off” button and the Chronograph is 

ready to record data.

 To turn unit off - depress “On/Off” button and hold for approximately 

3-5 seconds. 

4 RCBS AmmoMaster

®

Chronograph Instructions

Advertising