5.4.6 Venting and evacuating

Venting can take place into the discharge line or
upstream of the discharge valve.
A venting line can also be used as a bypass, drain or
flushing line.
The pump housing is fitted with a drain connection as
a standard feature. Optionally, the drain bore can be
drilled.

Fig. 4

5.5 Pipe fittings

The following pipe fittings are available from Richter
on request:

Check valves
Shut-off valves
Sight glasses
Priming vessels
Strainers
Pressure gauges

Fig. 5

5.6 Monitoring facilities

Appropriate monitoring facilities are to be
recommended,

depending

on

the

requirements placed on operational safety

and availability of the unit.
Richter provides information on request and can
supply:

Flow meters
Filling level indicators
Motor load monitors
Temperature monitors
Rolling bearing monitors
Can monitors
Leak monitors
SAFERUN

®

Condition Monitoring System

You can obtain the publications "Safe Operation of
Magnetic Drive Pumps" and "The Operation of
Centrifugal Pumps without NPSH Problems" on
request.

5.7 Drive

The power consumption of the pump at the operating
design point is specified in the data sheet and works
certificate. If the operating design point was not known
when the pump was dispatched, the power
consumption can be read off the appropriate
performance curves. The max. density, the max.
viscosity and a safety margin are to be allowed for.
Care must be taken when selecting the motor size to
ensure that the excess power is not too great. During
start-up the magnetic drive could otherwise stop.
The magnetic drive rating at the required pump speed
is given in the pump data sheet.
If the motor rating exceeds this magnetic drive rating –
at pump speed -, it is necessary to check for any
stoppage of the magnetic drive.
This also applies if the required drive rating exceeds
80% of the magnetic drive rating – at pump speed.
Consult Richter if necessary.
Different operating data can be achieved without
changing the pump through the use of different
speeds, e.g. by means of a frequency converter.
The pump with base plate and motor is illustrated in
the installation drawing.
The operating manual of the motor manufacturer
must be observed.

A motor with a valid ATEX certificate is to be
used if employed in zone 1 and 2.