1 intended use, Directive 94/9/ ec (atex), Intended use – Richter GSO Series Strainers User Manual

Page 6: Series gso

Advertising
background image

Series GSO

Page 6

9540-061-en

Revision 10

TM 8361

Edition 10/2011

3

Safety notes for applications in potentially explosive areas
based on the Directive 94/9/ EC (Atex)

The valves are intended for use in a potentially
explosive area and are therefore subject to the
conformity assessment procedure of the directive
94/9/EC (ATEX).
As part of this conformity assessment, an ignition
hazard analysis to EN 13463-1 to satisfy the
fundamental safety and health requirements was
conducted with the following result:

The valves do not have any ignition source of
their own.

The valves are not covered by the scope of
application of the ATEX directive and therefore
do not need to be identified accordingly.

The valves may be used in a potentially
explosive area.

It is imperative to observe the individual points of
intended use for application in a potentially explosive
area.

3.1 Intended use

Improper operation, even for brief periods, may
result in serious damage to the valve.
In connection with explosion protection, potential
sources of ignition (overheating, electrostatic and
induced charges, mechanical and electric sparks)
may result from these improper operation; their
occurrence can only be prevented by adhering to
the intended use.
Furthermore, reference is made in this connection to
the Directive 95/C332/06 (ATEX 118a) which contains
the

minimum

regulations

for

improving

the

occupational health and safety of the workers who
may be at risk from an explosive atmosphere.

A difference is made between two cases for the use of
chargeable liquids (conductivity < 10

-8

S/m):

1. Chargeable liquid and non-conductive

lining

Charges can occur on the lining surface. As a
result, this can produce discharges inside the
valve. However, these discharges cannot cause
ignitions if the valve is completely filled with
medium.
If the valve is not completely filled with medium,
e.g. during evacuation and filling, the formation of
an explosive atmosphere must be prevented, e.g.
by superimposing a layer of nitrogen. It is
recommended to wait 1 hour before removing the
valve from the plant in order to permit the
elimination of static peak charges.

This means that, to safely prevent ignitions, the
valve must be completely filled with medium at all
times or else a potentially explosive atmosphere
must be excluded by superimposing a layer of inert
gas.

2. Chargeable liquid and conductive lining

No hazardous charges can occur as charges are
discharged direct via the lining and shell (surface
resistance <10

9

Ohm, leakage resistance <10

6

Ohm).

Static discharges of non-conductive linings are
only produced through the interaction with a
non-conductive medium and are therefore the
responsibility of the plant operator.
Static discharges are not sources of ignition which
stem from the valves themselves!

The temperature of the medium must not exceed
the temperature of the corresponding temperature
class or the maximum admissible medium
temperature as per the operating manual.
If the valve is heated (e.g. heating jacket), it must
be

ensured

that

the

temperature

classes

prescribed in the Annex are observed.
To achieve safe and reliable operation, it must be
ensured in inspections at regular intervals that the
valve is properly serviced and kept in technically
perfect order.
Increased wear to the valve can be expected with
the conveyance of liquids containing abrasive
constituents. The inspection intervals should be
reduced compared with the usual times.
Actuators and electric peripherals, such as

temperature, pressure and flow sensors etc., must
comply with the valid safety requirements and
explosion protection provisions.

The valve must be grounded.
This can be achieved in the simplest way via the
pipe screws using tooth lock washers.
Otherwise grounding must be ensured by different
measures e.g. a cable link.

Plastic-lined valves must not be operated with
carbon disulphide