1 intended use, Intended use, Series hv, hvr – Richter HVR Series Bellows-Sealed Valves User Manual

Page 7: Installation and operating manual

Advertising
background image

Installation and Operating Manual

Series HV, HVR

9520-050-en

Revision 01

TM 6128 MPE/Wm

Page 7

Edition

04/2005

3

Safety notes for applications in potentially explosive areas
based on the Directive 94/9/ EC (Atex 95)

The valves are intended for use in a potentially
explosive area and are therefore subject to the
conformity assessment procedure of the directive
94/9/EC (ATEX).
As part of this conformity assessment, an ignition
hazard analysis to EN 13463-1 to satisfy the
fundamental safety and health requirements was
conducted with the following result:

The valves do not have any ignition source of
their own.
The valves are not covered by the scope of
application of the ATEX directive and therefore
do not need to be identified accordingly.
The valves may be used in a potentially
explosive area.

It is imperative to observe the individual points of
intended use for application in a potentially explosive
area.

3.1 Intended

use

Inadmissible modes of operation, even for brief
periods, may result in serious damage to the
valve.
In connection with explosion protection, potential
sources of ignition (overheating, electrostatic and
induced charges, mechanical and electric sparks)
may result from these inadmissible modes of
operation; their occurrence can only be prevented
by adhering to the intended use.
Furthermore, reference is made in this connection to
the Directive 95/C332/06 (ATEX 118a) which contains
the minimum regulations for improving the occupa-
tional health and safety of the workers who may be at
risk from an explosive atmosphere.
A difference is made between two cases for the use
of chargeable liquids (conductivity < 10

-8

S/m):

1. Chargeable liquid and non-conductive

lining

Chargeable liquid and non-conductive lining
Charges can occur on the lining surface. As long
as the valve is completely filled with medium, no
hazardous discharges can result from these
charges.
As a result, this can produce discharges inside the
valve. However, these discharges cannot cause
ignitions if the valve is completely filled with
medium.
If the valve is not completely filled with medium,
e.g. during evacuation and filling, the formation of
an explosive atmosphere must be prevented, e.g.
by superimposing a layer of nitrogen. It is recom-
mended to wait 1 hour before removing the valve

from the plant in order to permit the elimination of
static peak charges.
This means that, to safely prevent ignitions, the
valve must be completely filled with medium at all
times or else a potentially explosive atmosphere
must be excluded by superimposing a layer of
inert gas.

2. Chargeable liquid and conductive lining

No hazardous charges can occur as charges are
discharged direct via the lining and shell (surface
resistance

<

10

9

Ohm, leakage resistance

<

10

6

Ohm)
The following special feature applies to the series
with bellows (HV, BAV, KSE, GU, GUT, PA):
The bellows are not offered in a conductive ver-
sion, i.e. the restrictions under point 1. apply.
Richter optionally offers conductive metallic bel-
lows for the series HV.
Static discharges of non-conductive linings
are only produced through the interaction with
a non-conductive medium and are therefore
the responsibility of the plant operator.
Static discharges are not sources of ignition
which stem from the valves themselves!
The temperature of the medium must not exceed
the temperature of the corresponding temperature
class or the maximum admissible medium tem-
perature as per the operating manual.
If the valve is heated (e.g. heating jacket), it must
be ensured that the temperature classes pre-
scribed in the Annex are observed.
To achieve safe and reliable operation, it must be
ensured in inspections at regular intervals that the
valve is properly serviced and kept in technically
perfect order.
Increased wear to the valve can be expected with
the conveyance of liquids containing abrasive
constituents. The inspection intervals are to be
reduced compared with the usual times.
Actuators and electric peripherals, such as
temperature, pressure and flow sensors etc., must
comply with the valid safety requirements and
explosion protection provisions.
The valve must be grounded.

This can be achieved in the simplest way via the
pipe screws using tooth lock washers.
Otherwise grounding must be ensured by other
action, e.g. cable bridges.

Plastic-lined valves must not be operated with
carbon disulphide.

Advertising