Cleveland Range 36-CGM-16-300 User Manual

Page 2

Advertising
background image

(NOT TO SCALE)

SECT.

III

PAGE

28

1007

Litho in U.S.A

Right - 6”, Left - 6”, Rear - 6” (12”

on control side if adjoining wall or

equipment is over 30” high for

service access)

For use in non-

combustible locations.

Contact factory for

variances to clearances

Do not use PVC pipe for drain.

Each compartment has capacity for:

Eight, 12˝ x 20˝ x 2

1

2

˝ deep Cafeteria Pans. Can

accomodate 18˝ x 26˝ Bun Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards

whether untreated or pre-treated, based upon 10 hours of

use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site

water analysis for recommendations concerning steam

generator feed water treatment (if required), in order to

remove or reduce harmful concentrations of minerals. The

use of highly mineralized water will mean that more

frequent servicing of the steam generator will be

necessary. The fact that a water supply is potable is not

proof that it will be suitable for the generator.

NOTES:

**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA (AGA, CGA).

** Do not connect to GFI

outlet. See note below.

Advertising