5 flow rate value kv [m³/h, 6 weights (ca. kg), Dimensions – Richter NKP Series Butterfly Valves User Manual

Page 6: Flow rate value kv [m³/h, Weights (ca. kg), Series nkl, nklp, nks, nksp, nk, nkp, 4 dimensions

Advertising
background image

Series NKL, NKLP, NKS, NKSP, NK, NKP

Page 6

9520-070-en

Revision 04

TM 7113

Edition 05/2008

1.4 Dimensions

Nom. size[

E

1

T

1

L

2

Connection

3

[mm]

[inch]

[mm]

[mm]

[mm]

50

2“

28

4

43

F07

80

3“

67

17,5

46

F07

100

4“

87

24,5

52

F07

150

6“

142

48

56

F10

200

8“

193

71

60

F10

250

10“

243

92

68

F12

300

12“

292

112

78

F12

350

14“

343

137

78

F14

400

16“

389

150

102

F14


1

See also Section 6.4, paragraph 1

2

Face to face to DIN EN 558-1, series 20 (ISO 5752, series 20)

3

Connections for worm gears and brackets as per DIN ISO 5211


The inside diameter of the mounted pipe flanges must always be greater than the di-
mension E in the table!
For more dimensions, see drawings in Section 10.

1.5 Flow rate value kv [m³/h]

Angel of opening

Nom. Size

[mm]

[inch]

20°

30°

40°

50°

60°

70°

80°

90°

50

2“

1

6

13

24

41

67

104

120

80

3“

5

22

47

82

126

197

264

282

100

4“

11

27

52

93

155

247

412

456

150

6“

37

84

164

276

431

702

1126

1254

200

8“

62

170

354

532

912

1371

2212

2503

250

10“

85

285

512

882

1451

2256

3692

4083

300

12“

159

421

835

1378

2282

3633

5735

6512

350

14“

230

610

1210

2000

3300

5270

8320

9450

400

16“

295

780

1550

2560

4240

6750

10650

12100

1.6 Weights (ca. kg)

Nom. size

Lug style body

Sandwich-

body

Double-flange

body

[mm]

[inch]

open

staff ende

open

staff ende

open

staff ende

Lever

Gear

50

2“

4,5

3,5

4,0

0,7

4,0

80

3“

7,5

4,5

5,0

0,7

4,0

100

4“

9,5

6,0

7,0

0,7

4,0

150

6“

16,0

11,0

12,0

3,7

4,5

200

8“

23,0

15,0

19,5

3,7

4,5

250

10“

35,0

25,0

29,0

--

9,5

300

12“

54,0

33,0

47,5

--

9,5

350

14“

68,0

47,0

--

--

15,0

Advertising