Sky-Watcher AZ114 MOUNT User Manual

Page 10

Advertising
background image

10

Both the star alignment methods provide alignment adequate for any visual observing purpose. For

applications that require extra high precision in a particular part of the sky, the SynScan

TM

AZ provides a

Pointing Accuracy Enhancement (PAE) function to further improve the accuracy. The PAE can be

performed in up to 85 zones to cover the whole sky. The area(s) where the chosen alignment star(s) is located

should be already mapped out accurately by the SynScan

TM

AZ. Further accuracy enhancement is not

necessary. The following provides a step-by-step procedure on how to perform PAE:

Use the direction keys to center the last go-to object, then go to the next step. (This step may be

skipped.)

Press and hold down the ESC key for 2 seconds. The hand control will display "Re-center" and

the name of the reference object will appear in a blinking mode (3 times). If the go-to command is

sent from the planetarium software, instead of the name of the object, the hand control will

display "Last goto object".

Make sure that the reference object is still in the center of the view and press ENTER. If you do

not wish to record the result, press ESC to abort the operation. After pressing ENTER, the

SynScan

TM

will record the amount of pointing inaccuracy and recalculate the model of the sky.

Now the pointing accuracy of this particular part of the sky should be greatly improved.

1.

2.

3.

The result for the star alignments and PAE is stored in the hand control even after the power

has been shut off. You will only need to perform the star alignment once as long as these two

criteria are met: 1. The telescope is moved to its home position (Park the telescope) before

turning off the power. 2. The telescope setup, including the mount, has not been moved.

Accessory change is acceptable as long as it is done with great caution. When the hand control

is turned on for the next time, make sure that the time entered during initial setup is based on

the same source as last time. For example, if you enter the time on your watch during this

observing session, the time you enter next time should also be read from your watch.

P

ointing Accuracy Enhancement (PAE)

1.

2.

3.

4.

In the alignment screen, select 2-Star Align using the scroll keys. Press ENTER to confirm.

The SynScan

TM

AZ will provide a list of stars available in your current sky for you to choose as the

first alignment star. Using the scroll keys, choose a star you are most familiar with and press

ENTER. The telescope will not automatically slew to the first selected alignment star. Use the

directional buttons to manually slew the telescope to point to the object. Now look through the

eyepiece and adjust the telescope so that the object is centered in the field of view of the

eyepiece. Press ENTER to confirm.

SynScan

TM

AZ will now provide a list of objects for the second alignment star. Choose a star using

the scroll keys and press ENTER. The telescope will start slewing towards the chosen object.

When the slewing stops, adjust the telescope with the directional keys until the star is centered on

the crosshairs in the finder scope. Repeat the centering procedure to center the object in the field

of the eyepiece and press ENTER to confirm.

If both alignment stars are properly aligned, "Alignment Successful" will display on the LCD.

Otherwise, the warning "Alignment Failed" will show and the alignment will have to be done again.

Two-Star Alignment

The two star alignment procedure is similar to the Brightest Star alignment, except that the hand control

will not prompt for you to select a directional region for a bright star. Below describes a step-by-step

procedure on how to perform the Two-Star Alignment:

Following is some pointers on how to choose appropriate alignment stars:
Select two stars that are at least 60 degrees apart. The more distance between the two alignment

stars, the better accuracy the alignment will produce. Choosing two stars with the same altitude in

elevation will also create a better result.

Advertising
This manual is related to the following products: