Troubleshooting chart – Campbell Hausfeld FP204100 User Manual

Page 5

Advertising
background image

5

FP204100

www.chpower.com

troubleshooting Chart

Symptom

Possible Cause(s)

Corrective action

Compressor will not run

1. Switch in OFF position

2. No electrical power at wall outlet

3. Compressor has reached automatic shut-

off pressure

4. Motor overheated

5. Blown fuse (inside pump cover)

6. Pressure switch bad

1. Make sure compressor is plugged in and

switch is ON

2. Check circuit breaker or fuse at electrical

panel.

3. Release air from tank until compressor

restarts automatically

4. Allow compressor to cool for approximately

30 minutes so thermal overload switch
will reset. Make sure compressor is run
in a clean, well-ventilated area where
temperature will not exceed 100°F.

5. Disconnect compressor from power source

then remove pump cover. Replace fuse –
Part. No. FP200352AV. If replacement fuse
blows, call 1-800-543-6400.

6. Replace pressure switch

Knocks, rattles, excessive vibration

1. Tank not level
2. Defective bearing on eccentric or motor

shaft

3. Cylinder or piston ring is worn or scored

1. Shim tank to level position
2. Replace pump assembly

3. Replace pump assembly

Tank pressure drops when compressor

shuts off

1. Loose drain valve
2. Check valve leaking
3. Loose connections (fittings, tubing, etc.)

1. Tighten drain valve
2. Replace check valve
3. Check all connections with soap and water

solution. If a leak is detected, tighten.
Or remove fitting and apply pipe tape to
threads and reassemble.

Do not disassemble

check valve. With air

in tank, bleed tank first.

Compressor runs continuously and air

output is lower than normal/low
discharge pressure

1. Excessive air usage, compressor too small

2. Loose connections (fittings, tubing, etc.)

3. Broken inlet valves
4. Piston ring worn

1. Decrease usage or purchase unit with

higher air delivery (SCFM)

2. Check all connections with soap and water

solution. If a leak is detected, tighten.
Or remove fitting and apply pipe tape to
threads and reassemble.

3. Replace pump assembly
4. Replace piston assembly

Excessive moisture in discharge air

1. Excessive water in tank
2. High humidity

1. Drain tank, tilt tank to remove moisture
2. Move to area of less humidity; use air line

filter

nOte: Water condensation is not caused by

compressor malfunction