Master switch programming mode, Momentary switch programming mode – SoundOff Signal INTELLIswitch990 60 Amp Digital Switch User Manual

Page 2

Advertising
background image

Switches 2 - 6 (5 switches total) can be associated with the Master Switch.

To Enter Master Switch Program Mode:
1. Press and hold switches 1 and 2 for 5-seconds (

pictured above):

All switch back light LEDs will blink ON and OFF twice.
This indicates that panel is in Master Switch Program Mode.

2. Press each switch (S2 - S6 above) that you want to associate with the Master Switch one (1) time:

All switches will flash when associated with the Master Switch.

3. Press switch a second (2nd) time to dis-associate it with the Master Switch:

Switch will stop flashing.

4. To exit Momentary Switch Program Mode, press Switch 1 a second (2nd) time:

All of the switch LEDs will execute a chase pattern as program mode exits.

Programming Notes:
1. Switches cannot be associated with the Master Switch and be programmed as a Momentary output
at the same time. The Master Switch overrides any Momentary programming.
2. The last program command will override any previously programmed command for any given switch.

IE. If switch 4 is associated with the Master Switch then programmed as a momentary switch,
it will no longer be associated with the Master Switch.

S1 & S2

Master Switch Programming Mode

S1

S2

S3

S4

S5

S6

Press and Hold

5-seconds

Switches flash to indicate
they are associated to the
Master Switch Program
Mode.

Press and Hold

5-seconds

Program Master Switch

Program Momentary Switch

Panel Front View

All Switches are factory set at Latching (Press ON / Press OFF).
Switches 2 - 5 (4 switches total) can be set as momentary (ON only when switch is held).
Switch 6 can be set as a 8-second timed momentary output (Press ON - Active for 8-seconds / Auto OFF).

To Enter Momentary Switch Program Mode:
1. Press and hold switches 5 and 6 for 5-seconds (

pictured above):

All switch back light LEDs will blink ON and OFF twice.
This indicates that panel is in Momentary Switch Program Mode.

2. Press each switch (S2 - S5 above) that you want to program as momentary one (1) time:

All switches selected as momentary will flash while in Momentary Program Mode.

3. Press switch a second (2nd) time to return it to Latching mode:

Switch will stop flashing.

4. To exit Momentary Switch Program Mode, press Switch 1 a second (2nd) time:

All of the switch LEDs will execute a chase pattern as program mode exits.

To Program Switch 6 as Timed Momentary (can be performed at same time as steps above):
1. Repeat Step 1 above.
2. Press and hold Switch 6 for as long as you want the timer to run during operation
(Between 1-second & 8-seconds).
3. Repeat Step 4 above.

S5 & S6

Momentary Switch Programming Mode

To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product please visit our website at www.soundoffsignal.com
and select the “Warranty & Returns” link along the left column of our home page. If you have questions regarding this product please contact Technical
Services, Monday - Friday, 8 am to 5 pm at 1.800.338.7337, press #4 to skip the automated message. Questions or comments that do not require
immediate attention may be emailed to [email protected].

1.800.338.7337 / www.soundoffsignal.com / Thank you for trusting us with your safety!