Cr series woodburning fireplaces, Chimney requirements - offset installations, 30˚ elbow offsets – Vermont Casting CR36L User Manual

Page 5

Advertising
background image

5

CR Series Woodburning Fireplaces

20001316

0 0 0 0 0

3”

11”

1 0 0 0 0

8¹⁄₄"

20"

0 1 0 0 0 11¹⁄₄" 25¹⁄₄"
2 0 0 0 0 13¹⁄₂" 29¹⁄₄"
1 1 0 0 0 16¹⁄₂" 34¹⁄₄"
0 0 1 0 0 20¹⁄₄" 40³⁄₄"
2 1 0 0 0 21³⁄₄" 43¹⁄₂"
0 0 0 1 0 26¹⁄₄" 51¹⁄₄"
0 1 1 0 0 28¹⁄₂" 55¹⁄₄"
1 0 0 1 0 31¹⁄₂" 60¹⁄₄”
0 1 0 1 0 34¹⁄₂" 65¹⁄₂"
0 0 2 0 0 37¹⁄₂" 70³⁄₄"
1 1 0 1 1 41¹⁄₂" 77³⁄₄"
0 0 1 1 1

45" 83³⁄₄"

0 1 2 0 1 47¹⁄₄" 87¹⁄₂"
0 0 0 2 1

51"

94"

0 1 1 1 1 53¹⁄₄"

98"

0 0 3 0 1 56¹⁄₄" 103¹⁄₄"
0 1 0 2 1 59¹⁄₄" 108¹⁄₂"
0 0 2 1 1 62¹⁄₄" 113¹⁄₂"
0 1 3 0 1 64¹⁄₂" 117¹⁄₂"
0 0 1 2 1 68¹⁄₄"

124"

0 1 2 1 1 70¹⁄₂"

128"

0 0 0 3 1 74¹⁄₄" 134¹⁄₂"
0 1 1 2 2

78" 140³⁄₄"

0 0 3 1 2

81"

146"

0 1 0 3 2

84" 151¹⁄₄"

0 0 2 2 2

87" 156¹⁄₂"

0 1 3 1 2 89¹⁄₄" 160¹⁄₄"
0 0 1 3 2

93" 166³⁄₄"

0 1 2 2 2 95¹⁄₄" 170³⁄₄"
0 0 0 4 2 99¹⁄₄" 177³⁄₄"
0 1 1 3 2 101¹⁄₄" 181³⁄₄"
0 0 3 2 2 104¹⁄₄" 186¹⁄₄"
0 1 0 4 2 107¹⁄₄" 191¹⁄₂"
0 0 2 3 2 110¹⁄₄" 196³⁄₄"
0 1 3 2 3

114" 203¹⁄₄"

0 0 1 4 3 117³⁄₄" 209³⁄₄"
0 1 2 3 3

120" 213¹⁄₂"

0 0 0 5 3 123³⁄₄"

220"

D

B

G

H

B

C

E

6 FT.

G

H

A

FP269CR

CR Series

2/19/99 djt

30˚ Elbow Offsets

1’ 1¹⁄₂' 3’ 4’

Offset

Rise

Chimney

Support

Illustration Key

The following safety rules apply to offset
installations. (The letters correspond with
letters above):
A. Height of the chimney measured from

the hearth to the chimney exit at top:

CR36L/R Series

Maximum:

90’0”

Minimum:

Without elbows

14’ 0”

With 2 elbows

15’ 0”

With 4 elbows

21’ 0”

B. Do not use more than four elbows per

chimney.

Attach the straps of the top elbows to a
structural framing member.

The first elbow of any pair does not have
straps.

C. The chimney cannot be more than 30°

from the vertical plane.

D. The maximum length of the angled run

of the total chimney system is 20 feet. (G
plus H cannot exceed 20 feet)

E. A chimney support (Model SKCS8) is

required every 6 feet of angled run of
chimney. Chimney supports are required
at 30 feet and 60 feet of chimney height
above the hearth also.

Determine the offset distance of your chim-
ney arrangement from the centerline of the
fireplace to the centerline of the chimney
where it is to pass through the first ceiling.

NOTE: This offset distance may not be your
full offset distance. See Examples 2 and 3.

Chimney Flue Exit

Chimney

Section

Elbow

Rise

Offset

Hearth Floor

Example 1

Example 2

Example 3

30°

Offset

Elbow

30°

Offset

Elbow

30°

Return

Elbow

30°

Return

Elbow

SKCS8

Support

NOTE: G + H Cannot Exceed 20’

Fig. 3 Chimney system requirements.

FP269CR

Chimney Requirements - Offset Installations