tekmar 269 One Stage Steam Control User Manual

Data brochure, D 269, One stage steam control 269

Advertising
background image

Copyright © D 269 - 06/00

1 of 12

9

One Stage Steam Control 269

10

Sen

Com

Sen

Com

11 12

Sen

Cnd Out

Steam

Established

Min. On Time (%)

Lockout Diff'l (

°F)

Test

Do not apply power here

Sen

Occupied

40
(4)

100
(38)

70

°F

(21

°C)

Unoccupied

40
(4)

100
(38)

70

°F

(21

°C)

H1099

with Early Start

13 14 15

Boiler

Power

Steam
Established

Heating
Cycle

UnOcc.

Auxiliary

WWSD

Early Start

Warning

Use Nº 20 AWG or larger copper conductors rated for at least 75

°C and 300V.

R

R

LR 58223

E150539

Listed

5T62

Date

S/N

2093
1234567

Power: 120V 50/60Hz 3VA
Relays: 120Vac 10A 1/4 hp 240VA, 2A pilot duty
Enclosed Energy Management Equipment

Manufactured

in Canada by

180

°F

130

230

Design Out

-40

0

°F

40

Off

25

50

5

Auto

45%

100

0

Man. Override

N

L

1

2

3

4

5

Power

6

S2

10K

Sw

UnO

S1

10K

Aux.

Warn.

1

50 min

100

10

Cycle Length

Early Start

1

2

3

4

Off

7

8

Boiler

Indoor Sensor S1
Indoor Sensor S2
Condensate Return Sensor

- Data Brochure

One Stage Steam Control 269

D 269

06/00

The tekmar One Stage Steam Control 269 is a microprocessor-based control which regulates the
firing time of a steam boiler based on user settings, outdoor air temperature, condensate return
temperature, and optionally, the indoor air temperature(s). The steam boiler can be operated in
the outdoor reset mode, or in Manual Override mode based on dial settings. The control has built-
in diagnostics for sensor checking with a Warning output for error reporting. Other control
operation features include Auxiliary relay output, Steam Established and Lockout Differential
temperatures, and Early Start with setback limit when using the Unoccupied input.

R

R

LR 58233

E150539

One Stage Steam Control 259

Occupied

40
(4)

100
(38)

70

°F

(21

°C)

Unoccupied

40
(4)

100
(38)

70

°F

(21

°C)

with Early Start

Boiler

Power

Steam
established

Heating
cycle

UnOcc.

Auxiliary

WWSD

Early Start

Warning

120 Vac

power supply

Output:

Warning Relay

Output:

Auxiliary Relay

Output:

Turn on boiler

Input: Indoor

Sensor 074

Optional

Input:
Unoccupied
signal

Optional

Test button and
LED to test main
control functions

System design
outdoor
temperature
setting

Heating cycle
length setting

Steam
established
(condensate
temperature)
setting

Minimum on
time/lockout
differential
setting

Terminal Plugs:

Power and out-

put connections

Boiler is on

Unoccupied

temperature

setting

Occupied

temperature

setting

Sensor Fault

warning

System is in

Unoccupied

mode

System is in

Warm Weather

Shut Down

Manual
override setting

Operating Mode

selector switches

Auxiliary relay

output is on

R

R

Outdoor Reset Strategy . . pg. 2
Sequence of Operation . . . pg. 3
Installation . . . . . . . . . . . . . pg. 6
Settings . . . . . . . . . . . . . . . pg. 8

Testing . . . . . . . . . . pg. 9
Error Messages . . . pg. 11
Technical Data . . . . pg. 12
Limited Warranty . . pg. 12

Early Start

into or

out of UnOcc.

Condensate

temperature is

established

120Vac power

supply is on

Heating Cycle

is in progress

Input: Indoor

Sensor 074

Optional

Input: Outdoor
Sensor 070. Included

Input: Condensate
Return Sensor 071.
Included