tekmar 316 tN4 Wiring Center Installation User Manual

Installation & operation manual, D 316, Benefi ts

Advertising
background image

1 of 12

© 2011

D 316 - 05/11

tN4 Wiring Center 316

D 316

05/11

Zoning

Replaces: 04/09

Installation & Operation Manual

Power

Zone 1

Zone 2

Zone 3

Zone 4

End Switch

tN4 Wiring Center 316

Four Zone Pumps

Input Power: 24 V (ac) ±10% 60 Hz
Class

2

Control Load: 11 VA
End Switch: 24 V (ac) 2 A
Pump Relays: 115 V (ac) 5 A
Zone Power: 115 V (ac) 12 A

Made in Canada

tektra 1031-01

Benefi ts

Simple, convenient wiring location
Compact enclosure for flexible installation
Reduce equipment cycling when combined with
tekmarNet

®

4 Thermostats



The tekmarNet

®

4 Wiring Center 316 is designed to operate up

to four zone pumps in a hydronic heating system. It provides a
convenient location to wire both thermostats and zone pumps
while only requiring two wires to integrate with the rest of the
mechanical equipment. The 316 is optimized for use with
tekmarNet

®

4 Thermostats. These thermostats communicate

with the tN4 Wiring Center to provide a synchronized end
switch that reduces cycling of equipment.

Features

Four 115 V (ac) powered zone outputs
For use with tekmarNet

®

4 Thermostats

tN4 expansion terminals
Isolated end switch
External diagnostic LEDs
CSA C US Certified for use in USA and Canada






Introduction

Notes

Not for use with tekmarNet

®

2 Thermostats