Example
A user switch has been installed together with two thermostats.
The thermostats are located in the master bedroom and
the guest bedroom.

User switch button 1 is labeled “Normal”.

User switch button 2 is labeled “Guest”.

User switch button 3 is labeled “Away”.

The master bedroom is programmed to operate at the
programmable setback schedule while in “Normal” and
“Guest” scenes.

The guest thermostat is programmed to operate at the
unoccupied temperature while in “Normal” scene and at the
programmable setback schedule while in “Guest” scene.

In this example, when a guest arrives to stay the night, the
“Guest” button can be pressed and the Guest Bedroom
temperature will operate on a programmable setback
schedule.

Once the guest leaves, press the “Normal” button to lower the
Guest Bedroom to the unoccupied temperature setting.

The following table shows how the thermostats respond
to each button:

Button

Master Bedroom

Action

Guest Bedroom

Action

“Normal”

Setback Schedule

Unoccupied

“Guest”

Setback Schedule

Setback Schedule

“Away”

Away

Away

Setpoint Controls

In addition to scenes, the user switch can also be programmed
to enable and disable individual setpoint controls or groups
of setpoint controls by pressing the user switch button.
These controls can regulate the temperature of devices
such as a hot tub or a radiant floor.

When a user switch button configured for setpoint controls
is pressed, the setpoint control changes the operational
setpoint from the unoccupied to the occupied temperature.
The setpoint control has a timer setting that counts down,
and when the timer expires, the setpoint device changes
back to the unoccupied temperature. Also, if the user switch
button is pressed a 2nd time, the setpoint device operation
changes back to the unoccupied temperature.

Press the “Hot Tub” button and the Hot Tub operates
for the set time.

COLD

User

Button

1

User

Button

2

User

Button

3

UnOcc

Setpoint

Control

Press the “Hot Tub” button while the Setpoint Control is
running to disable the Hot Tub.

User

Button

1

User

Button

2

User

Button

3

HOT

Set Time

3:00 hr

Setpoint

Control

User

Button

1

User

Button

2

User

Button

3

HOT

Run Time

2:17hr

Setpoint

Control

COLD

User

Button

1

User

Button

2

User

Button

3

UnOcc

Setpoint

Control