tekmar M3061 Mixing Valve Adapter Kit User Manual

Data brochure, D 016, Step one getting ready

Advertising
background image

1 of 4

Copyright © D 016 -10/00

- Data Brochure

4 – Way Mixing Valves 016 – 026

10/00

D 016

9

8

7 6

5 4 3 2

1

2

3

4

5

6

7

8

Sequence of Operation

Installation of tekmar 4–Way Mixing Valves

STEP ONE

GETTING READY

Check the contents of this package. If any of the items listed below are missing or damaged, please refer to the Limited Warranty
and Product Return Procedure on the back of this brochure and contact your wholesaler or local tekmar representative.

Types 016 - 019 includes

• One Mixing Valve & One Data Brochure D 016

Types 024 - 026 includes

• One Mixing Valve & One Data Brochure D 016

STEP TWO

MOUNTING

Note If types 024-026 are assembled and welded “in place”, the flap assembly must be removed from the valve body when welding

since excessive heat will damage the internal rubber seals. Also, do not use the valve body to "square" the flanges.

The tekmar 4 – Way Mixing Valves 016 - 026 mix supply water from a source with water returning
from a system. The valve can be automatically operated by utilizing a tekmar Actuating Motor and
a floating action control signal. This precision valve is manufactured to the highest quality standards
for a long trouble free service. It is designed for use in closed loop hydronic systems with properly
treated water. The valve provides a maximum of 1% leak through rate to allow for water expansion
during temperature changes. The valve ports are characterized to provide a proportional water
temperature change relative to the scale on the face plate of the valve.

When the valve flap is in the fully closed
position, 100% of the boiler supply wa-
ter is returned to the boiler and 100% of
the heating system return water is sup-
plied to the system. When the valve flap
is in the fully open position, 100% of the
boiler supply water enters the heating
system and 100% of the heating system
return water returns to the boiler. Mixing
of the water takes place when the valve
flap is in an intermediate position.

Supply From
Boiler

Supply T

o

System

Return

T

o

Boiler

Return From
System

R

e

tu

rn

T

o

B

o

ile

r

Return From

System

S

u

p

p

ly

T

o

S

y

s

te

m

Supply From

Boiler

Valve flap in the open

position

Valve flap in the closed

position

Valve flap in an intermediate

(mixing) position

S

u

p

p

ly

T

o

S

y

s

te

m

Return From

System

Su

pply From

Boile

r

R

e

tu

rn

to

B

o

ile

r

Configuration Options

Configuration

Wiring

As Delivered,

No changes required.

Note: The tear drop shaped ports
are the outlets to the boiler and to

the system.

Turn the valve over until the

handle's pointer and marker pegs

are pointing down. Remove marker

pegs and re-install in upper two

holes. Remove the handle, rotate it

180

° and re-install it.

to system

to boiler

from
boiler

#1

9

0

from

system

from
system

to system

to boiler

9

0

from

boiler

Valve

Closed

#2

Valve

Closed

REVERSE
THE WIRES

Mixing valve control

Cls
Mix

Opn

Mix

Actuating motor

Opn

2

Com

C

1

Cls

3

Actuating motor

NO
CHANGE

Mixing valve control

Cls
Mix

Opn

Mix

Opn

2

Com

C

1

Cls

3

Advertising