tekmar 420 Boiler Reset Module User Manual

Data brochure, D 420, Features

Advertising
background image

D 420

08/07

- Data Brochure

Boiler Reset Module 420

1 of 24

© 2007

D 420 - 08/07

• tN4 Compatible

• Boiler Outdoor Reset

• Single On-Off or Modulating Boiler

• Powered Pump Outputs

• Setpoint Operation

• DHW Operation

• Includes Sensors

Features:

Information

Brochure

Choose controls

to match

application

1

Application

Brochure

Design your

mechanical

applications

2

Wiring

Brochure

Wiring and

installation of

specific control

4

Job

Record

Record settings &

wiring details for

future reference

6

Data

Brochure

Control settings

and sequence of

operation

5

Rough-in

Wiring

Rough-in

wiring

instructions

3

The Boiler Reset Module 420 provides outdoor reset to a hydronic heating system in order to maximize comfort and
efficiency. The 420 can operate a single on / off boiler or a single modulating boiler. The 420 can override the outdoor reset
water temperature to provide Domestic Hot Water or Setpoint operations.

Introduction

51 52

53 54 55

56

57 58

60

61

62 63 64

Boiler

DHW

Setpoint

C

59

C

Com Boil Out

Vlv

Demand

Demand

24 V (ac)

DHW

R

65

+

Mod (dc)

DHW

Primary

10 A

max.

66

67

68

69

N

Pump

N

Pump

tN4

H7006B

Boil On-Off / Mod
Off / tekmar Stager

Powered

Output 1 VA

DHW Valve:
24 V (ac) 8 VA

Made in Canada

Meets Class B: Canadian
ICES & FCC Part 15

Test

Boiler Reset Module 420

Item

Menu

tektra 991-01

Demands: 20 - 260 V (ac)
Relay Rating: 115 V (ac) 5 A

/

Do not apply power