Crown Audio XLS 202 User Manual

Xls 202, Architectural & engineering specifi cations

Advertising
background image

Crown International
P.O. Box 1000
Elkhart, IN 46515-1000
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com

XLS 202

09/03 135167-2

Specifi cations subject to change without prior notice. Latest
information available at www.crownaudio.com.
Crown is a registered trademark of Crown International.
Other trademarks are the property of their respective owners.
Printed in U.S.A.
© 2003 Crown Audio, Inc.

Architectural & Engineering Specifi cations

X L S S E R I E S

XLS 202 (120 V, 60 Hz models)

The power amplifi er shall be a solid-state two-channel model.

The amplifi er shall provide extensive protection and diagnostic capabilities, including
output current limiting, DC protection, circuit breaker, and special thermal protection
for the unit’s transformers.

The front-panel controls shall be two black detented level controls (one for each
channel), a power switch, and a circuit breaker for overload protection.

Front-mounted indicators shall be Clip: one red LED per channel which illuminates
when the channel’s output signal is being overdriven, Power: one green LED which
indicates that the amplifi er has been turned on and AC power is available, and Fault:
one yellow LED which illuminates when amplifi er is in protect mode and briefl y
during normal power-up when amplifi er is fi rst switched on.

The recommended load impedance shall be 2 to 8 ohms per channel in Stereo, and
8 ohms in Bridge Mono. The amplifi er shall be safe when driving any kind of load,
including highly reactive ones.

The rear-mounted output connectors shall be

one four-pole Speakon

®

connector and

a pair of 5-way binding posts per channel. Rear-mounted input connectors shall be
3-pin balanced XLR connectors.

The power amplifi er shall meet or exceed the following performance criteria: Input
sensitivity for rated output at 4 ohms: 0.725 V. Rated output with both channels driven
with 0.5% THD (at 1 kHz) in Dual mode: 250 watts per channel into 2 ohms, 200
watts per channel into 4 ohms, and 145 watts per channel into 8 ohms. Rated output
with 0.5% THD (at 1 kHz) in Bridge-Mono mode: 400 watts into 8 ohms and 500
watts into 4 ohms. Frequency Response at 1 watt, 20 Hz to 20 kHz: ±0.75 dB. Phase
Response at 1 watt: –10 degrees at 10 Hz, +19 degrees at 20 kHz. Signal to Noise
Ratio below rated power (20 Hz to 20 kHz): greater than 100 dB A-weighted. Total
Harmonic Distortion at full rated power, 1 kHz: less than 0.15%. Intermodulation
Distortion (60 Hz and 7 kHz at 4:1, from full rated output to –40 dB: less than 0.3%.
Damping Factor (8 ohms): greater than 200 from 10 to 400 Hz. Crosstalk (below rated
power, –82 dB at 1 kHz, –58 dB at 20 kHz. Voltage Gain at maximum output: 31 dB.
Input Impedance (nominal): 20 kilohms balanced, 10 kilohms unbalanced. AC Line
Voltages and Frequencies Available (±10%): 120 VAC/60Hz and 230 VAC/50 Hz.

The amplifi er chassis shall be constructed of steel with a durable black fi nish and
shall be designed for fl ow-through ventilation from the front panel to the back
panel. Internal heat sinks with forced-air cooling shall provide rapid, uniform heat
dissipation.

The dimensions of the amplifi er shall allow for 19 inch (48.3 cm) EIA standard (RS-
310-B) rack mounting. The amplifi er shall be 3.5 inches (8.9 cm) tall, and 14 inches
(35.6 cm) deep behind the rack-mounting surface.

The amplifi er shall weigh 21.0 pounds (9.5 kg).

The amplifi er shall be designated the Crown XLS 202.

Advertising