Tests and Certifications

Product  Safety  Evaluation

• UL Standards 8750 (Recognized Component), 1598C (LED Retrofit Kit)
• CSA Standard C22.2 No. 250.0-08
• ENEC License ENEC-00404 —tested according to EN 62031:2008 (Ta
55°C Tc 85°C)

Radio  Frequency  Emissions

FCC  Part  15,  Unintentional  Radiators  Class  A

Reduction  of  Hazardous  Substances  (RoHS)

European  Council  Directive  2002/95/EC

Input  Current

Current  :  =  120  mA

Input  Voltage  Range/Frequency  Range

90VAC—300VAC  /  47Hz—63Hz

Power  Factor

0.90

Electrical  Fast  Transients

IEC/EN  61000-­‐4-­‐5  ±1  kV

Surge

Voltage  Harmonics

IEC/EN  61000-­‐4-­‐5  ±500V  Differential  mode  /  ±1  kV  Common  mode

IEC/EN  61000-­‐3-­‐2

Voltage  Dips  and  Interrupts

Mains  dips  of  30%  for  500ms,  95%  for  10ms,  and  interruptions  of  95%  
for  5s

Electrostatic  Discharge

±  6  kV  Contact  mode,  ±  10  kV  Air  Gap

Shock  and  Vibration

Operating  –  Non  Operating

Impact

1  m  product  drop,  1.3  m  steel  ball  impact

Operating    Temperature

-­‐40°C  to  +55°C,  0  to  95%  R.H.  /  153  hr.

Storage  Temperature

-­‐40°C  to  +85°C  /  60  hr.  followed  by  20°C  to  85°C,  5  to  95%  R.H.  /  80  hr.

Ingress  Protection  (Water,  Dust)

IP65

Lumen  Maintenance  

L70  =60,000hr  per  IES  TM-­‐21-­‐11  (Based  on  LED  Manufacturer’s  
measurement  per  IES  LM-­‐80-­‐08  @  10.000hrs).  
To  be  extended  as  additional  data  becomes  available

Mean  Time  Between  Failures  (MTBF)  

100-277V - 4”: >530,000 Hrs.

 