TerraLUX Decorative MR16 LED Lamp Product Specification (04/01/2013) - Subject to change without notice

3

www.terraluxillumination.com

TESTS AND CERTIFICATIONS

Product Safety Certifications

 UL Standard 1993: Self Ballasted Lamps and Lamp Adaptors
 UL Standard 8750: LED Light Sources for Use In Lighting Products

 CSA C22.2 No. 1993-09: Self Ballasted Lamps and Lamp Adaptors

Radio Frequency Emissions

 FCC Part 15, Unintentional Radiators Class B.

Sec 107, Conducted Emissions - 0.15MHz – 30MHz

 Industry Canada Notice ICES-003: Class B Digital Apparatus

Reduction of Hazardous Substances
(RoHS)

European Council Directive 2002/95/EC, (including amendments 2005/618/EC,
2005/717/EC and 2005/747/EC) on the restriction of certain hazardous substances in
electrical and electronic equipment.

Electro-Static Discharge

IEC 61000-4-2: 2001-04 Electromagnetic Compatibility (EMC) - Part 4: Testing and
measurement Techniques - Section 2: Electrostatic Discharge (ESD) Immunity Test.

 ± 2kV and ± 4kV contact discharge to all exposed conductive (25 discharg-

es each polarity)

 ±6kV and ± 8kV air gap discharges to all non-conductive surfaces (25 dis-

charges each polarity)

Power Factor

0.67 @ 12 V AC/60Hz

Shock

Operating - 82 G peak, 2 ms; Half sine, 1 shock per second 20 shocks per axis, both di-
rections – total 120 shocks

Non-Operating - 120 G peak., 2 ms, Half sine, 1 shock/second, 3 shocks per axis, both
directions – total of 18 shocks
40 G Faired Square wave w/ velocity change of 62 in/sec. 1 shock per axis, both direc-
tions – total of 6 shocks

Vibration

Operating - Random PSD Spectrum G, 1.0G RMS, 10-2000 Hz. 30 minutes per axis 3-500
Hz., 0.50 g peak, swept sine @ ½ octave/min per axis
Non-Operating - Random PSD, 5 G RMS, 15 minutes per axis
5-500-5 Hz, 1.0 g peak, Swept Sine @ ½ Octave per minute, per axis.

Shipping / Transit

International Safe Transit Association (ISTA) Project 2A.
Packaging details:

 11” x 4.5” x 3”, 1 layer, 10 units/box, weight = 1lbs 8oz

Operating Temperature

-40°C to +55°C, 0 to 95% R.H. / 153 hr.

Storage Temperature

-40°C to +85°C / 60 hr. followed by 20°C to 85°C, 5 to 95% R.H. / 80 hr.

Long Term Operation

100 samples of the TLL-R16A operated continuously for a cumulative operating runtime
equal to two times the 3 year warranty period, or 52,560 Hrs. During this test, a nominal
12Vac supply voltage was applied, and the samples were tested in a lab ambient tem-
perature environment.

Input Voltage Range

9.6—14.4 V AC/DC