Ledsense, Operation, thermal de-rating and lumen, Light output vs temperature – TERRALUX TLM-R08A User Manual

Page 4: Power vs. heatsink temperature

Advertising
background image

 

 

4  

TERRALUX TLM-R08A Product Specification – Subject to change without notice

 

WWW.TERRALUX.COM

5/23/2014

 

LEDSense

®

Operation, Thermal De-rating and Lumen

The TLM-R08A employs TERRALUX’s patented LEDSense

®

Thermal Management Technology to

automatically provide maximum light output in various fixtures and operating conditions while
assuring long-term lumen maintenance. LED-Sense

®

regularly measures the operating temperature

and ensures compliance with a pre-programmed temperature and drive-current profile. This profile
is based on the LED manufacturer’s LM-80 data report and minimum L70/60,000 hour lumen
maintenance curves. LEDSense

®

is always active, and will compensate for variation in thermal

conditions due to heatsinking, ambient air, engine positioning, or any other variable that affects the
operating temperature. The Thermal De-rating curve below identifies the relative light output that
can be expected under various thermal conditions. The LEDSense

®

Power Curve identifies the

reduction in input power over temperature.

0%  

10%  

20%  

30%  

40%  

50%  

60%  

70%  

80%  

90%  

100%  

110%  

25  

30  

35  

40  

45  

50  

55  

60  

65  

70  

75  

80  

%

o

f i

n

it

ia

l L

OP

Heatsink Temperature Tc [°C]

Light Output vs Temperature

0%  

10%  

20%  

30%  

40%  

50%  

60%  

70%  

80%  

90%  

100%  

110%  

25  

30  

35  

40  

45  

50  

55  

60  

65  

70  

75  

80  

%

o

f i

n

it

ia

l P

o

w

er

Heatsink Temperature Tc [°C]

Power vs. Heatsink Temperature

Advertising