1 installation, 1 unpacking, 2 locating / mounting surge – Trebor SS95 Surge Suppressor User Manual

Page 3: Installation, Unpacking, Locating / mounting surge

Advertising
background image

SS95 SURGE OPERATION / MAINTENANCE MANUAL

PAGE 3

1 INSTALLATION

1.1 UNPACKING

After unpacking, the Surge Suppressor should be checked for any damage that
may have occurred during shipment. Damage should be reported to the carrier
immediately.

The following items should be included within the shipping container:

Qty

Item

Description

1

SS95

SS95 Surge Suppressor

1 MSS95

Operation/Maintenance

Manual

1 **

Seal,

Port

**Dependent upon type of pump option selected.

1.2 LOCATING / MOUNTING SURGE

• Remove port plug from pump.
• Install new port seal.
• Hand tighten surge suppressor into port. Do not over tighten.

ATTENTION: Over-tightening adapter into pump will result in pump damage.

• Run 1/8 bleed line to drain. In the event of a diaphragm failure fluid may flow

through tube to drain.

• Connect air supply using 3/8” or larger air line. Air supply to Surge

Suppressor must be equal to or greater than pump supply pressure.

NOTE: When connecting the SS95 to an externally controlled pump, do not
connect the SS95 air supply via a tee from the pump. Connect to a separate
continuous supply.