Troubleshooting chart, Mw2500 series – Campbell Hausfeld IN634000AV User Manual

Page 6

Advertising
background image

Operating Instructions and Parts List

6

www.chpower.com

MW2500 Series

troubleshooting chart

Symptom

Possible cause(s)

corrective action

Compressor will not run

1. Switch in OFF position

1. Make sure compressor is plugged in and switch is ON.

2. No electrical power at wall outlet

2. Check circuit breaker or fuse at electrical panel.

3. Compressor has reached automatic

shutoff pressure

3. Release air from tank until compressor restarts automatically.

4. Motor overheated

4. Allow compressor to cool for approximately 30 minutes so

thermal overload switch will reset. Make sure compressor is
run in a clean, well-ventilated area.

5. Pressure switch bad

5. Replace pressure switch.

Thermal overload
protector cuts out
repeatedly

1. Low voltage

1. Check voltage at wall outlet with voltmeter.

2. Wrong gauge wire or length of

extension cord

2. Check extension cord chart for proper extension cord usage.

3. Lack of proper ventilation/room

temperature too high

3. Move compressor to well-ventilated area. Ambient

temperature must be below 104°F for proper operation.

4. Defective check valve

4. Repair or replace.

5. Defective unloader valve (on

pressure switch)

5. Repair or replace.

6. Compressor valves failed

6. Replace valve assembly.

Do not disassemble check valve with

air pressure in tank; bleed tank.

Tank pressure drops when
compressor shuts off

1. Loose connections at fittings,

tubing, air line, or tool

1. Check all connections with soap and water solution. If a leak

is detected, (1) tighten or (2) remove fitting and apply pipe
tape to threads and reassemble.

2. Loose drain valve

2. Tighten.

3. Check valve leaking

3. Remove check valve. Clean or replace.

4. Tank leaks

4. Check tank for leaks with soap and water solution. If leak is

detected, tank must be replaced with genuine replacement
part.

Do not disassemble check valve with

air pressure in tank; bleed tank.

Compressor runs
continuously and air
output is lower than
normal/low discharge
pressure

1. Excessive air usage, compressor too

small

1. Decrease usage or purchase unit with higher air delivery

(SCFM).

2. Loose connections at fittings,

tubing, air line, or tool

2. Check all connections with soap and water solution. If a leak

is detected, (1) tighten or (2) remove fitting and apply pipe
tape to threads and reassemble.

3. Tank leaks

3. Check tank for leaks with soap and water solution. If leak is

detected, tank must be replaced with genuine replacement
part.

4. Broken valves

4. Replace compressor valves as necessary.

5. Piston ring worn

5. Replace piston ring.

Excessive moisture in
discharge air

1. Excessive water in tank

1. Drain tank.

2. High humidity

2. Move to area of less humidity; use air line filter.
nOte: Water condensation is not caused by compressor

malfunction.

Safety valve pops open

1. Defective pressure switch

1. Replace pressure switch.

2. Defective safety valve

2. Replace safety valve with genuine replacement part.