Troubleshooting guide – Tundra HTS3024 User Manual

Page 9

Advertising
background image

HTS-324_1224-GD-0114-EN

9

6.2

Troubleshooting guide

Problem

Possible cause

Solution

Fault indicator ON

Low input voltage






High input voltage

Short circuit or AC wiring error



Inverter overload

Not enough battery capacity

Recharge batteries

Improper Installation. Check each
inverter’s installation steps

Check vehicle’s alternator condition

Check the AC wiring (120 volts) and test
your appliances on an other power supply
to validate their functionality

Remove or reduce load, switch the
inverter OFF at least 5 second and restart
the inverter

No output voltage

Inverter off

No DC power to the inverter




Reverse DC polarity

Turn the inverter on

Check the wiring

Check battery fuse et check the
installation before changing it

Replace internal fuses of the inverter.
Damage caused by reversed polarity is not
covered by the warranty.

Alarm on all the time

Poor battery condition

Poor DC wiring


Poor DC terminal lugs connections

Charge or change battery

Use proper cables and make solid
connections

Use proper crimping tool

Overheat

Thermal shutdown

Improper installation

Reduce load

Allow inverter to cool off

Improve ventilation

Install properly