07 primary power cable connections, 07 primary power cable connections -3 – Tweco Merlin 6000 Plasma Cutting CE Slave Power Supply User Manual

Page 19

Advertising
background image

Manual 0-2603

3-3

INSTALLATION PROCEDURES

11

12

L3

13

15

14

6

7

L2

8

10

9

1

2

L1

3

5

4

Busbar Connections

For Input Voltage

Of 380/415 VAC

A-01090

Figure 3-4 Busbar Connections

If necessary, reposition the busbars to correspond to
the available line voltage.

3.07 Primary Power Cable

Connections

WARNING

Disconnect primary power at the source before con-
necting the primary power cable to the power sup-
ply.

The primary power cable must be supplied by the end
user and installed to the Power Supply assembly. Rec-
ommended cable sizes are specified in Appendix 1.

NOTE

Three-phase operation requires a 3-conductor cable
with ground.

1. Route the primary power cable through the strain

relief fitting in the rear panel of the Power Sup-
ply and tighten strain relief screws.

Input Power

Filter PC Board

and Bracket

Primary Power

Cable

Strain Relief

Fitting

Input Ground

Connection

A-00896

L1

L2

L3

Figure 3-5 Input Voltage Connections

2. Locate the four input connectors, flat washers,

conical spring washers, and hex locking nuts sup-
plied with the power supply.

3. Install the input connectors, supplied, onto each

of the input power line leads of the power cable.

Input

Connector

Input Power Cable

(One Line)

Slotted Screw

A-00908

PC Board

Power Stud

Flat Washer

Conical Spring

Washer

Hex Locking

Nut

Figure 3-6 Input Voltage Connector Installation

Detail

Advertising