INSTALLATION PROCEDURES

3-14

Manual 0-2653

E. Gas Control Module Connection

The Gas Control Module (GCM6000) allows setting pressures
and flows of various multiple plasma and secondary gases con-
nected to the Power Supply. The proper plasma and secondary
gas is selected with switches on the front panel of the Gas
Control Module. The pressures and flows are set for the se-
lected gases with pressure regulators and flowmeters on the
front panel.

1. Connect the Gas Control Module control cable to the

connector marked GAS CONTROL (J55) on the rear
panel of the Power Supply.

2. Connect the other end of the cable to the Gas Control

Module rear panel J56 connector.

NOTE

Refer to the Gas Control Module Instruction
Manual 0-2641 for more information on the
GCM6000 Gas Control Module.

A-01767

Cable From

Gas Control Module

GAS

CONTROL J55

Connector

Figure 3-18 Optional Gas Control Interface Connection

3.13 Master/Slave Parallel Cable

Connection

The interface between the Master and Slave Power Sup-
ply is made through the Parallel Cable. Connect one end
of the cable to the rear of the Master Power Supply at
PARALLEL CONNECTOR J54. The other end connects
to the rear of the Slave Power Supply at J15.

A-01769

Cable To

Slave Power Supply

PARALLEL

CONNECTOR J54

Figure 3-19 Parallel Cable Connection

3.14 Lifting Options

WARNING

Do not lift a power supply equipped with a cylin-
der rack running gear.

The recommended method for lifting the power supply
is to use a forklift as follows:

1. Approach from the front or rear of the unit.

2. Place the forks between the rear wheels or the front

casters.

3. Center the forks under the unit and carefully check for

proper balance before lifting.