Manual 0-2478

15

INSTALLATION PROCEDURES

set for closed contact which means that no con-
nection equals standoff active and normal current.
It may be set so that an open connection activates
the CSD function.

Activate CNC

Function with:

CSD

SW1-1

Station Select

SW1-2

Open Contact

ON

OFF*

Closed Contact

OFF*

ON

* = Factory Setting

SW1

CNC Station Select/

CSD Contact Selection

Remote Control

PC Board Assembly

A-00677

2

1

ON

Figure 3-9 Switch SW1 Location

B. Switch SW2 Selections

OK-To-Move Activation Switch (SW2) - The OK-
To-Move signal may be set to activate either at pilot
start or arc transfer.

If the application requires starting the torch off the
edge of the workpiece this selection should be set
to activate at pilot start.

O K-To-Move Activation

SW 2-1

SW 2-2

Activate at Pilot Start

O N

O N

Activate at Arc Transfer

O FF *

O FF *

* = Factory Setting

SW2

OK-To-Move

Activation Selection

Remote Control

PC Board Assembly

A-00678

2

1

ON

Figure 3-10 Switch SW2 Location

C. OK-To-Move Jumper Selections

The OK-To-Move signal may be selected by either a con-
tact closure or 24 VAC switched through the contact. The
Remote Control is factory-set for dry contacts. The pur-
pose of selecting 24 VAC is to drive a relay coil whose
current must not exceed 150 ma or solid state relays in
cutting machine controllers.

Advertising