Ultra-cut 400, 01 installation requirements – Tweco 400 Ultra-Cut User Manual

Page 27

Advertising
background image

Manual No. 0-5164

3-1 INSTALLATION

ULTRA-CUT 400

SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This
conformity shall be checked by qualified personnel.

Ultra-Cut 400 Power Supply

Input

Power Input Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps) Wire (AWG) Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

208

50/60

119

336

350

300MCM

150

230

50/60

119

304

350

250MCM

150

460

50/60

116

148

175

#1

50

380

50/60

120

183

225

1/0

70

400

50/60

120

174

225

1/0

70

* Suggested wire size based on United States NFPA 70 National Electrical Code 2005 edi-

tion published by the National Fire Prevention Association.

Listings are from table 400.5(B) for flexible cord of certain types rated for 75 deg C in

ambient temperatures up to 30 deg C. Using wires of lower temperature rating or differ-

ent insulation type may require larger wire size. Derate for higher ambient.

These are suggestions only. Always refer to your local and national codes that apply to

your region for final determination of correct wire type and size.

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for

the type and method of wire being used.

Gas Supply

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure

regulators must be double-stage and installed as close as possible to the gas console. Contaminated gas
can cause one or more of the following problems:

• Reduced cutting speed
• Poor cut quality
• Poor cutting precision
• Reduced consumables life.
• Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).

Advertising