Manual No. 0-4805 Auto-Cut 200

3-26

INSTALLATION

Complete the Installation

1. Fill the coolant tank to the level shown, with Thermal Dynamics coolant. The coolant level is visible

through the translucent coolant tank. The amount of coolant required varies with torch leads length.

2. Replace the cap on the tank.

Cat. Number and Mixture

Mixture

Protects To

7-3580 'Extra-Cool

TM

'

25 / 75

10° F / -12° C

7-3581 'Ultra-Cool

TM

'

50 / 50

27° F / -33° C

7-3582 'Extreme Cool

T M

'

Concentrate*

-65° F / -51° C

Coolant Capabilities

* For mixing with D-I Cool

TM

7-3583

RETURN

SUPPLY

RETURN

SUPPLY

Art # A-04803

COOLANT

Fill Range

Coolant Tank

2. After the complete system has been installed, check that the coolant has been pumped through the system

as follows (see NOTE):

Advertising