Ultra-cut 300 – Tweco 300 Ultra-Cut(March 2013) User Manual

Page 30

Advertising
background image

INSTALLATION

3-6

Manual No. 0-5134

ULTRA-CUT 300

Check / Adjust Input Voltage Configuration for 208/230 and 460V Systems

1. The 208/230 and 460 V power supply includes a voltage configuration board which must be positioned to

match the primary input voltage. Remove the power supply left side panel and locate the voltage configuration
board. The input voltage configuration is shown at the top of the board.

2. If necessary, disconnect the jumper at the top right corner of the board, remove the board and re-install it with

the correct input voltage shown at the top of the board.

3. Re-connect the jumper. Re-install the power supply side panel.

Art # A-04856_AB

1. Unplug connector

2. Remove bolts.
3. Invert board.
4. Re-install board.
5. Plug in connector.

208/230V / 460V

Input Voltage Board

(Shown in 460V Position)

Inverter Module