3.04 Specifications





































Thermal Arc continuously strives to produce the best product possible and therefore reserves
the right to change, improve or revise the specifications or design of this or any product without
prior notice. Such updates or changes do not entitle the buyer of equipment previously sold or
shipped to the corresponding changes, updates, improvements or replacement of such items.

Parameter 400

TS

Rated Output
Amperes
Volts
Duty Cycle

208-230/460VAC
400
36
25%

Duty Cycle

400A / 36V @ 25% (3ph)
300A / 32V @ 60% (3ph)
300A / 32V @ 25% (1ph)

Output Current Range

5 – 400 Amps

Open Circuit Voltage

65V

Dimensions
Width
Height
Length


8.3” (210mm)
16.5” (420mm)
17.7” (450mm)

Weight

52.9 lb. 24 kg

Output @ Rated Load
Rated Input Voltage
Output Amperes
Output Volts
Duty Cycle
KVA
KW

Three-phase
208-230/460V
400A
36V
25%
24.0
18.0

Single-phase
208-230V
300A
32V
25%
20.0
12.0

Output @ No Load
KVA
KW


0.5
0.13

Input Volts Three Phase

208V
230V
460V

Input Volts Single Phase

208V
230V

Amperage Draw

@ Rated Load

67
61
31

97
87

No Load

1.4
1.3
0.7

2.5
2.2

Advertising