3.04 Mains Supply Voltage Requirements

The Mains supply voltage should be within ± 10% of the rated Mains supply voltage. Too low a voltage may cause poor
welding performance or the wirefeeder malfunction. Too high a supply voltage will cause components to overheat and
possibly fail. The Fabricator 190 is supplied with a 10 AWG x 3 supply lead.

Install a power outlet for each Power Supply and fit fuses as per the machine specifications.

!

WARNING

Thermal Arc advises that your Fabricator be electrically connected by a qualified electrical trades-person.

The Fabricator 190 Power Supply is factory connected for the following input power supply voltage:

Input Power

Supply Lead Size

Lead Current

Rating

Lead

Length

Machine

Voltage Setting

Duty Cycle

10 AWG x 3

40 Amps

10ft (3m)

230V

190A @ 15%

Table 3-1: Factory Fitted Input Power Supply Leads Fitted to the Fabricator 190

3.05 Alternative Mains Supply Voltages

!

WARNING

The Fabricator 190 input power supply lead should be replaced with leads as specified in Table 3-2 when
the Fabricators input power supply voltage is changed.

The Power Supply is suitable for use on the following input power supply voltages:

Input Power Supply

Voltage Setting

Primary Input

Power Lead Size Lead Length

Input Power

Outlet Size

Fuse Size

Duty Cycle

208V 1ø

10AWG (5mm2)

3M

50 Amps

45 Amp

250A @ 30%

230V 1ø

10AWG (5mm2)

3M

50 Amps

45 Amp

250A @ 30%

Table 3-2: Mains Supply Lead Sizes for Alternative Mains Supply Voltages

3. Remove the black wire from the current location and

Insert the uninsulated wires into the new voltage lo-
cation. Secure by tightening the set screw onto the
uninsulated portion of the wires. Secure the first set
screw as well.

National Electrical Code Standards permit the rating of
the fuse or thermal circuit breaker protecting the circuit
conductors to be double the standard rating for any circuit
used exclusively for an electric arc welder. Check local
requirements for your situation in this regard.

Changing the Voltage Selection

1. Disconnect the power supply from the main power

source.

2. Refer to Figure 3-1. The power supply comes wired

for 230V. Locate the black input power wire secured
to the input voltage selection block. Loosen the set
screw for both voltage locations.

Art # A-08417

Figure 3-1: Voltage selections for Fabricator 190