0 voltage reduction device (vrd), 01 vrd specification, 02 vrd maintenance – Tweco 185TSW DC CC User Manual

Page 49: 01 vrd specification 11.02 vrd maintenance

Advertising
background image

49

11.0 Voltage Reduction Device (VRD)

11.01 VRD Specification

Description

Pro-Wave

185TSW

Notes

VRD Open Circuit Voltage

15.3 to 19.8V

Open circuit voltage between welding
terminals.

VRD Resistance

148 to 193 ohms

The required resistance between welding
terminals to turn ON the welding power.

VRD Turn OFF Time

0.2 to 0.3 seconds The time taken to turn OFF the welding

power once the welding current has
stopped.

11.02 VRD Maintenance

Routine inspection and testing (power source)

An inspection of the power source, an insulation resistance test and an earth resistance test
should be carried out

a) For transportable equipment, at least once every 3 months; and

b) For fixed equipment, at least once every 12 months.

The owners of the equipment shall keep a suitable record of the periodic tests.

Note 7

A transportable power source is any equipment that is not permanently connected and
fixed in the position in which it is operated.

In addition to the above tests and specifically in relation to the VRD fitted to this machine,
the following periodic tests should also be conducted by an accredited Thermal Arc service
agent.

Description

IEC 60974-1 Requirements

VRD Open Circuit Voltage

Less than 20V; at Vin=230V

VRD Turn ON Resistance

Less than 200 ohms

VRD Turn OFF Time

Less than 0.3 seconds

If this equipment is used in a hazardous location or environments with a high risk of
electrocution then the above tests should be carried out prior to installation at this location.

Advertising
This manual is related to the following products: