3.01 Environment

These units are designed for use in environments with

increased hazard of electric shock as outlined in IEC

60974.5.
A. Examples of environments with increased hazard of

electric shock are:
1. In locations in which freedom of movement is re-

stricted, so that the operator is forced to perform the

work in a cramped (kneeling, sitting or lying) position

with physical contact with conductive parts.

2. In locations which are fully or partially limited by con-

ductive elements, and in which there is a high risk of

unavoidable or accidental contact by the operator.

3. In wet or damp hot locations where humidity or per-

spiration considerably reduces the skin resistance

of the human body and the insulation properties of

accessories.

B. Environments with increased hazard of electric shock

do not include places where electrically conductive parts in

the near vicinity of the operator, which can cause increased

hazard, have been insulated.

3.02 Location

Be sure to locate the welder according to the following

guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 0° C to 40° C.
C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or shock.
E. In areas, not exposed to direct sunlight or rain.
F. The enclosure design of this Wire Feeder meets the

requirements of IP23S as outlined in AS60529. This

provides adequate protection against solid objects

(greater than 12mm), and direct protection from verti-

cal drops. Under no circumstances should the unit be

operated or connected in a micro environment that will

exceed the stated conditions. For further information

please refer to AS 60529.

G. Precautions must be taken against the Wire Feeder

toppling over. The Wire Feeder must be located on

a suitable horizontal surface in the upright position

when in use.

SECTION 3: INSTALLATION OPERATION AND SETUP

WARNING

This equipment should be electrically

connected by a qualified electrician.

3.03 Ventilation

!

WARNING

Since the inhalation of welding fumes can

be harmful, ensure that the welding area is

effectively ventilated.

3.04 Mains Supply Voltage

Requirements

See Operating Manual for Transmig 250i.

3.05 Electromagnetic Compatibility

!

WARNING

Extra precautions for Electromagnetic

Compatibility may be required when this

Welding Power Source is used in a domestic

situation.

A. Installation and Use - Users Responsibility

The user is responsible for installing and using the welding

equipment according to the manufacturer’s instructions.

If electromagnetic disturbances are detected then it shall

be the responsibility of the user of the welding equipment

to resolve the situation with the technical assistance of

the manufacturer. In some cases this remedial action

may be as simple as earthing the welding circuit, see

NOTE below. In other cases it could involve constructing

an electromagnetic screen enclosing the Welding Power

Source and the work, complete with associated input

filters. In all cases, electromagnetic disturbances shall be

reduced to the point where they are no longer Trouble-

some.