SERVICE

5-6

Manual 0-2967

B. AC indicator

flashing; Torch cannot be activated

1. System is in protective interlock mode. (User held torch trigger while turning on ON / OFF switch.)

a. Release torch trigger, set ON / OFF switch to OFF (down). Return ON / OFF switch to ON (up) position.

2. System is in protective interlock mode. (Torch parts are missing or loose.)

a. Release torch trigger, and set ON / OFF switch to OFF (down). Open main disconnect switch. Check torch

parts, including O - rings on torch head. Refer to illustration in Section 5.03-C-E. Replace parts as needed.
Reinstall shield cup; hand - tighten it securely against the torch head. Close main disconnect switch. Set ON
/ OFF switch to ON (up) position.

3. System is in protective interlock mode. (Torch connection to power supply is loose.)

a. Release torch trigger, and set ON / OFF switch to OFF (down). Tighten torch connector to receptacle on

power supply securely. Do not use tools. Set ON / OFF switch to ON (up).

4. System is in protective interlock mode. (User removed shield cup from torch while power supply ON / OFF switch was

ON.)

a. Release torch trigger, and set ON / OFF switch to OFF (down). Set ON / OFF switch to ON (up).

C. Torch will not pilot; AC indicator

ON, Gas indicator

OFF

1. Gas pressure below minimum for power supply operation

a. Set gas pressure to 65 psi / 4.5 bar

D. Torch will not pilot; AC indicator

ON, Gas indicator

ON (on system start-up); Gas indicator goes out

when user presses torch trigger

1. Gas pressure below minimum for torch operation

a. Set gas pressure to 65 psi / 4.5 bar

E. AC indicator

flashing; Temp indicator flashing slowly

1. Fan disconnected or blocked.

a. Clear fan if blocked; let power supply cool off.

b. Connect wires to fan if necessary.