03 input wiring specifications, 03 input wiring specifications -2 – Tweco PC-500 User Manual
Page 16
INTRODUCTION
2-2
Manual 0-4601
Power Supply Dimensions & Weight
Ventilation Clearance Requirements
22.5"
0.57 m
58 lb / 26 kg
A-03700
10.75"
273 mm
16.375"
416 mm
6"
150 mm
A-03379
6"
150 mm
6"
150 mm
6"
150 mm
2.03 Input Wiring Specifications
Voltage
Freq.
1-Ph
3-Ph
1-Ph
3-Ph
(Volts)
(Hz.)
(kVA)
(kVA)
(Amps) (Amps)
1-Ph
3-Ph
1-Ph
3-Ph
1-Ph
3-Ph
208
60
9
39
60
10
10
230
60
9
37
60
10
10
Fuse (Amps)
Wire (AWG)
Wire (Canada)
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
PC-500 Power Supply Input Wiring Requirements
Input
Power Input
Current Input
Suggested Sizes (See Notes)
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations refer
to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS / LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.