Weller WSD130 User Manual

Page 4

Advertising
background image

4

9

STARTING

Assemble soldering iron stands. Place the soldering irons in stands. Insert the soldering iron connectors into sockets (6)
and (8) on the control unit and lock by turning slightly to the right. Check whether the supply voltage matches with the
information on the rating plate and that the power switch (1) is in the off position.

Connect the control unit to the power supply 120 VAC (10). Switch on the unit at the power switch (1). When the unit is
switched on, a self-test is performed during which all the display elements (2) are operating. The temperature set (target
value) on the activated channel is then briefly displayed along with the temperature scale (°C/°F). The electronics then
switches automatically to the current value display. LED (5) or (9) illuminates. These light emitting diodes are optical
regulator monitors. Continuous illumination means that the system is heating up. Flashing indicates that the operating
temperature has been reached.

A setback time of 20 minutes may be set by depressing the UP key while the station is switched

on; ON wil be displayed to indicate the SETBACK mode is set. Repeat the procedure to disable the SETBACK feature; OFF will be
displayed.

CHANNEL SELECTION

The digital display can be switched to channel 1 or 2 by pressing the channel selection button (7). The currently dis-
played channel is identified by a red/orange light emitting diode over connector (5) or (9).

The channel displayed can be switched off by operating the “Up” and “Down” buttons (3) and (4) simultaneously. This is
confirmed in the display with “Off”.

To activate a channel that has been switched off, the channel is selected, if necessary, using the channel selection button
and switched on by pressing “Up” and “Down” buttons (3) and (4) simultaneously. The current value is displayed in the
display.

19. Inspect the soldering tool for any damage.

Before further use of the soldering tool, safety devices or slightly damaged parts must be carefully checked
for error-free and intended operation. Inspect moving parts for error-free operation and that they don’t bind,
or whether any parts are damaged. All parts must be properly mounted and all requirements fulfilled for
guaranteed error-free operation of the soldering tool. Damaged safety devices and parts must be repaired or
replaced by a qualified technician, so long as nothing else is indicated in the Operation Manual.

20. Attention.

Use only accessories or attachments which are listed in the accessories list of the Operation Manual. Use
only Weller accessories or attachments on original Weller equipment. Use of other tools and other
accessories can lead to danger of injury.

21. Repairs to your soldering tool should be carried out by a qualified technician.

This soldering tool is in accordance with the relevant safety regulations. Repairs should only be carried out
by a qualified electrician using original Weller replacement parts. Failure to do so can lead to accidents for
the operator.

22. Do not work on electrically live parts.

The grip of antistatic designed soldering tools in conductive.

23. Application with other Weller equipment.

If the soldering tool is to be used together with other Weller equipment and attachments, also observe the
warning notices given in the corresponding Operation Manual.

24. Observe the valid safety regulations for your workplace.