Winchester Repeating Arms 1400 (Historic Manual) User Manual

Page 12

Advertising
background image

4. Do not pull trigger after

disassembly .

5.

The piston is under spring tension.

With the gun upright and the

magazine minted in a safe direction,

insert a screw driver or a suitable rod

into the coils of the closing spring at

the forward end of the slot in the top of

the magazine tube. Draw back on the

tool relieving the tension from the

piston. While holding the spring

compressed, remove the piston pin

that connects the slide arms to the

piston. Place your free hand over

the end of the magazine tube, then

remove the tool from the coils and

withdraw the piston and closing

spring from the end of the tube. Dis-

connect and remove the slide arms

from the receiver.

NOTE: When reassembling the coil

spring, place the end having the smaller

coils toward the breech end of the

magazine tube.

6. With the bolt assembly in the

receiver, disengage the cocking handle

bridge by first pushing the rear of the fir-

ing pin forward with your forefinger.

Holding the firing pin in this position, tilt

the front end of the cocking handle

bridge up and move it slightly forward,

detaching the bridge from the bolt slide.

Remove

the firing pin and spring.

7. Slide the breech bolt with the

cocking handle to the rear of the

receiver. Grasp the cocking handle

Advertising