CCI Thermal Technologies SHMK - Swivel Hanging Mounting Kit User Manual

Installer required to supply, Step 3, Step 4

Advertising
background image

Swivel Hanging Mounting Kit Installation Instructions

For Electric Heaters

WARNING:

If the heater is installed on a structure that is to be transported, provide additional support for the

heater during transit. The suspended weight should not exceed 300lbs (136kg).

Refer to the owner’s manual for mounting specifications and conditions.

Check that your heater model number corresponds to the model number shown on the mounting kit carton

.

Installer required to supply:

a)

A method of fastening the Angle Hangers to the supporting structure that is at least as strong

as four 3/8” diameter, grade 5 bolts (see step 1) and,

b)

two pieces of 1/2”, schedule 40 or heavier, steel pipe cut to suit required installation length

and threaded at both ends (see step 2).

STEP 1

Fasten Angle Hangers  to a

surface or structure that will

support the heater’s weight using

the installer supplied fasteners.

Refer to the owners’ manual for

the heater’s weight.

Printed in Canada. Copyright 2007. All rights reserved.

Part No. 5751-3

CONTENTS
Item Qty. Description

2 Angle Hanger

2 Connector Hanger

2 Adaptor Hanger

4 Bolt, 1/2 UNC x 1-1/4”

4 Nut, 1/2 UNC

4 Lock Washer, 1/2”

1 Mtg Attach Assy Bracket

1 Swivel Mtg Attach Assy

1 Flat Washer

1 Bolt, 5/8 UNC x 1-1/4”
1 Lock Washer, 5/8”

STEP 2

Screw one Connector

Hanger  and on Adaptor

hanger  onto each steel

pipe until tight (min. 5 turns

each).

STEP 3

Bolt Mtg Attach Assy Bracket 

to the heater using 1/2 UNC x

1-1/4 bolts, lock washers, and

1/2 UNC nuts.

STEP 4

Screw Hanger

Assemblies to the

Swivel Mtg Attach

Assy .

STEP 5

Hang assembly from Angle

Hangers  using two 1/2

UNC x 1-1/4” bolts, lock

washers, and nuts.

STEP 6

Hang assembly from Angle

Hangers using two 1/2 UNC x

1-1/4” bolts, lock washers, and

nuts.

Bolt the Swivel Mtg Attach Assy

to the Mtg Attach Assy Bracket

using a 1/2 UNC x 1-1/4” bolt, lock

washer, and flat washer. Swivel

heater to desired orientation and

secure in place.

Connector Hanger

must be

hung on the inside of Angle
Hanger

as shown. Rotate

Connector Hanger

to align

with Angle Hanger

. Do not

back off more than 3/4 turns.

Mtg Attach Assy Bracket

must be

placed with the threaded hole closest to

the control enclosure side of the heater.

Support structure

Installer supplied

fasteners

4-1/2”

(144mm)

10-1/8”

(258mm)

1/2” Sch. 40 or

heavier Steel pipe

Support structure



Heater

may be

rotated as

indicated

by arrows

Advertising