1.0 GENERAL INFORMATION

DESCRIPTION

CCI Thermal’s

XGB explosion-proof unit heater is the latest addition

to the

NORSEMAN™ line of hazardous location heating products.

The small cabinet units are available with ratings from 3.75 – 10kW,

and can be identified by their internally mounted motor. The large

cabinet units (shown below) are available from 10kW up to 35kW.

See section 3.1 for cabinet dimensions.

APPLICATION

Designed specifically for heating industrial spaces where potentially

explosive substances are or may be present. Typical hazardous

location environments include:

• Water and Sewage Treatment Plants

• Oil Refineries

• Compressor Stations

• Pulp and Paper Mills

• Paint Storage Booths

• Cement Plants

• Mines

CONSTRUCTION AND INSTALLATION

CCI Thermal’s

NORSEMAN™ unit heaters use extra heavy wall

finned tubular steel heating elements to provide safe, efficient heat

transfer to the environment. The heater does not contain glycol,

decreasing maintenance costs.

Flow adjustment… in structures with high ceilings, other units may

not have the range of motion needed to direct air flow to the floor.

The glycol-free design of the

XGB allows the unit to be tilted to

a 30º angle below the horizontal, with an additional 35º of airflow

redirection provided by the outlet louver. For lateral airflow, the

entire louver assembly can be rotated 90º.

No conduit seal required… a factory installed conduit seal provides

the necessary isolation between the supply and control housings.

In Division 2, Zone 1 and Zone 2 applications, a field installed

conduit seal may not be required.

Simplified wiring… to facilitate installation, the NORSEMAN™

explosion-proof unit heaters feature the patented

x-Max

®

housing

with slide out terminal block trolley for connection of the electrical

supply.

STANDARD PRODUCT FEATURES

• CSA C/US Certified for hazardous locations. Small cabinet units

approved for Class I, Div 1 & 2, Group D; Class II, Div. 1 & 2,

Groups E, F and G. Large cabinet units approved for Class I, Div.

1 & 2, Groups C & D; Class II, Div. 1 & 2, Groups E, F & G.

Note: Class II and some atmospheric groups are not available in

every kW rating.

• Optional Zone marking available.

• Ratings from 3.75 – 35kW.

• 208 – 600V, 1 or 3 phase

• Low watt density extra heavy wall tubular steel finned heating

elements with nickel plated finish

• Glycol-free design allows the heater to be tilted 30º downward

• Rotatable outlet louvers provide 35º of additional airflow

redirection

• Patented

x-Max

®

housing with track and trolley system simplifies

installation and servicing

• Heavy duty 16 ga. Stainless steel casing

• Terminals for remote thermostat connection

• Dual automatic reset high limits

• Contactor derated for extended service life

• Isolated supply connection housing eliminates the need for

conduit seals

OPTIONAL FEATURES

• Built-in, externally adjustable thermostat

• Built-in disconnect

• Moisture-resistant construction

• “Auto/off/fan-only” switch

• Pilot light

• Manual reset high limit

THERMOSTATS

CCI Thermal offers a wide variety of explosion-proof thermostats

to suit most every need.

NORSEMAN™ unit heaters are available

with optional built-in, externally adjustable, bulb type thermostats

which are field-convertible to tamper-proof. Thermostats for remote

mounting can also be provided on request.

MOTORS

Fractional horsepower, 1725 rpm explosion-proof motor with double

shielded ball bearings and built-in thermal overload. Small cabinet

units use 1/12 hp motor approved for Class I, Group D; Class II,

Group E, F, and G. Large cabinet units use 1/2 hp motor approved

for Class I, Groups C and D; Class II, Groups E, F & G, as standard.

ACCESSORIES

NORSEMAN™ explosion-proof unit heaters readily adapt to most

mounting requirements. Each heater is equipped with a basic swivel

bracket that is compatible with any of the optional mounting kits.

Optional mounting kits allow the unit to be installed on a wall ceiling,

3” pipe, or floor stand. Each mounting configuration provides

maximum flexibility for outlet flow direction. The swivel bracket

(standard on all heaters) features holes for affixing a safety chain.

Edmonton Head Office & Factory

5918 Roper Road, Edmonton, Alberta, Canada T6B 3E1

P 780.466.3178 F 780.468.5904 Toll Free 1.800.661.8529

[email protected] www.ccithermal.com

Installation, Operation & Maintenance Instructions for

NorsemanTM XGB Explosion-Proof Unit Heater

3.75 - 35kW, 60 Hz Units

Part No. 11110 - Rev. 02

GLYCOL

FREE

DESIGN

Advertising