*Battery History

Install Date

<50% DOD

Inits

<80% DOD

Terms

>80% DOD

<20% DOD

*Battery Information

Fleet ID

Voltage

Capacity

S/N

Tag ID

ML No

Cell Type


Language

English

Dansk

Francais

Svenska

Nederlands

Espanol

Deutsch


Charger options

Auto Balance

AGV

Onboard

Safety Disconnect

Stored Equalize

BattID


Settings

Set LCD Contrast

Reset Charger

Override / Enable Inhibit

The menu can be exited by pressing the BACK key.

* This menu item can only be selected if the charger has the BattID

option fitted.

Faults / Warnings

If a critical fault occurs during charge the

charge status indicator

will show indication 5 and the LCD Display will show the fault code

and description, for example:

Faults permanently stop charge until they are rectified.


If a warning occurs during charge the warning symbol

will be

displayed on t he LCD Display and t he warning code and

description can be ac cessed by scrolling through the charge

information.

Warnings do not affect the charge procedure.

Fault Codes


F06

No output current

F07

*

Incorrect battery

F09

*

Bulk charge timeout

F10

*

Gassing charge timeout

F12

Configuration error

F13

Thermistor fault

F17

*

Auto balance timeout

F18

Battery disconnected

F19

Battery disconnected during cooldown

F21

Over current

Warning Codes

F01

*

Over discharged battery

F02

*

Deep discharged battery

F03

*

Sulphated battery

F04

Charger overheating

F05

Mains Failed during charge

F23

Batt ID PCB error

F24

Batt ID Antenna error

F25

Batt ID Tag read error

F26

Batt ID not programmed

F27

** Slave 1 incorrect correct current

F28

** Slave 2 incorrect correct current

F29

** Slave 3 incorrect correct current

F30

** Slave 1 temperature fault

F31

** Slave 2 temperature fault

F32

** Slave 3 temperature fault

* = These faults are usually associated with the battery, check

battery condition.

** = Only applicable on models with dual power modules

Repair

Only suitably qualified personnel should perform repair work
on this equipment.

Use of genuine factory sourced replacement parts is necessary to

ensure UL marking is not invalidated.

Contact your local maintenance facility for assistance or

replacement parts. Always be prepared with the charger type and

serial number prior to placing a call for assistance.

Maintenance

Before carrying out maintenance, isolate the mains supply
and disconnect the battery.

Only suitably qualified personnel should perform
maintenance work on this equipment.

The charger will require little maintenance, but the following

schedule is recommended once a month:

(a)

Check the condition of all cables, paying particular

at

tention to the points where cables may be severely

flexed, i.e. at the entry to charger cabinet, charging plugs

and sockets.

(b)

Check condition of charging plugs and sockets for wear

and any evidence of overheating, which could ultimately

lead to charger malfunction.

(c)

Check that ventilation is not obstructed.

(d)

Ensure that all safety covers and panels are correctly in

place.