The Tubular-LM FP charging algorithm includes an unterminated Float Stage that begins automatically
once full charge is complete. The Float Stage holds the battery at 2.28 volts per cell (VPC) until the
battery is required for service. The result is that the battery is maintained at full state of charge which
helps to prevent self-discharge and sulfation.

WHEN IT IS TIME TO PUT THE BATTERY INTO SERVICE, REMOVE THE BATTERY FROM
THE CHARGER BY UNPLUGGING THE CHARGER POWER CORD FROM THE POWER
OUTLET AND THEN DISCONNECT THE CHARGER CABLE FROM THE BATTERY CABLE.

High “on charge” temperatures or frequent need for water additions are indications of overcharging.
Short running times and/or low end-of-charge specific gravities may indicate inadequate recharge.
Consult your local GNB Industrial Power representative on specific charging problems.

If the charger does not work correctly or if it has been damaged, unplug it immediately from the power
outlet and contact your local GNB Industrial Power service representative.

The charger may be provided with a thermal sensor connected to the top of the battery. With this
sensor, the charging profile will automatically compensate for variable battery temperatures. Do not
disconnect the sensor from the top of the battery or the charger.

The charger is equipped with a two-tone audible alarm. In the event of an alarm condition, the audible
alarm will sound and the LED indicator will flash. Possible alarm conditions are:

When there is an alarm, the charger stops supplying current to the battery.

Page 4

Condition

Alarm Type

Description (Action)

Audible message
+ RED flash

Battery Presence

Battery disconnected or not in conformity. (Verify
the connection and the nominal voltage).

Audible message
+ YELLOW flash

Thermal Sensor

The thermal sensor is disconnected during the
recharge or it is out working range. (Verify the
connection of the sensor and measure the tem-
perature of the battery).

Audible message
+ GREEN flash

Timeout

Phase 1 and/or Phase 2 have a duration in
excess of the maximum allowed. (Verify the bat-
tery capacity).

Audible message
+ RED-YELLOW flash

Battery Current

Loss of output Current control. (Failure of the con-
trol logic).

Audible message
+ RED-GREEN flash

Battery Voltage

Loss of output Voltage control. (Battery discon-
nected or failure of the control logic).

Audible message
+ YELLOW -GREEN flash

Selection

An unavailable configuration has been selected
(Verify the selector’s position).

Audible message
+ RED-YELLOW-GREEN flash

Thermal

Overheating of semiconductors. (Verify the fan
operation).