Cooper Lighting 1493 User Manual

Fail-safe, Mpwa, Medical/t ask & undercabinet

Advertising
background image

COOPER LIGHTING

FAIL-SAFE

®

MEDICAL/T

ASK & UNDERCABINET

• Up light: .125" thick,

prismatic K12 pattern,
acrylic lens is standard;
Down light: .125" thick,
contoured drape formed,
prismatic K12 pattern,
acrylic lens is standard

• Nickel-plated thumbscrews

are standard (requires no
tools to remove lens
assembly)

• Housing is 18 gauge, die-

formed, cold rolled steel
with seam-welded ends

• MPWA uses T8 Linear

Fluorescent or T5 HO
Linear Fluorescent

• Ballast Options include T8

Electronic Instant Start, T5
Electronic Programmed
Start and T8 Magnetic-HPF

• High gloss white polyester

powder coat finish is
standard on exterior
housing; interior reflector is
high reflectance white

• UL/CUL Listed for Damp

Locations

D I M E N S I O N S

D E S C R I P T I O N

Fail~Safe’s MPWA series
combines a multi-function, wall
mounted luminaire with the
architectural styling of today’s
healthcare environment.
Through innovative features,
the MPWA accommodates for
multiple applications
throughout the healthcare
environment while offering an
appealing and highly styled
design for all architectural
tastes. The MPWA luminaire
has been designed with the
patient and healthcare
professional in mind.

MPWA

5 1 W – 2 1 6 W

F l u o r e s c e n t

A R C H I T E C T U R A L

H E A LT H C A R E

W A L L M O U N T E D

L U M I N A I R E

1493

M O U N T I N G

O R D E R I N G I N F O R M AT I O N

S A M P L E N U M B E R : M P W A - 2 / 2 3 2 - 1 2 0 - E B 8 3 - E X L L - P S 4

Series
MPWA
= Medical

Patient
Wall
Architectural

Ballast
3 Electronic
Ballasts are
Standard

EB83=T8
EB53=T5

LEOC8=Magnetic
energy savings
ballast (T8 only,
min. 3 per fixture)

1

Switching Control
Options
PICK ONE BELOW
or (if no switching
option is specified,
fixture ships with
leads left unwired
for switch wiring
completed in field)

PS4=4 position
pull chain

2

PS1D=2 position

pull chain
(controls
bottom
lamp only,
upper
lamps on
separate
circuit)

2

LVCP=Low voltage

controller,
patient
controlled
(patient
controls all
lamps)

1

LVCF=Low voltage

controller,
facility
controlled
as needed

1

Finish Options
(If not specified, fixture ships with
standard high gloss white finish)
MF=Metallic Finish
DP=Dark Platinum
IH=Almond Finish
Custom Colors are available (specify or
supply sample, requires a flat fee, consult
customer service)
SSN=Stainless Steel Natural (brushed

finish)

SSP=Stainless Steel Painted (Standard

high gloss white or specify finish)
(i.e. SSP-DP)

Options
EBP
=Emergency battery pack

1

(no red, yellow, or green
charge light will be provided)

FNL=Fluorescent Night Light,

2-pin (G23 Base), 7 or 9w twin
tube (Lamps by others).

GCO=Grounded Convenience

Outlet, right side mounted
facing unit

2

(Non Hospital Grade Only)

GCOL=Grounded Convenience

Outlet, left side mounted
facing unit

2

GLR=Fuse and holder
NRLR=White LED Nurse Chart

Reading Light, right side
mounted facing unit

2

NRLL=White LED Nurse Chart

Reading Light, left side
mounted facing unit

2

RIF=Radio Interference Filter. For

use with T8 magnetic ballast
only (1 per ballast)

1

SFP=Machine Screws, Philips Head

Natural Stainless Steel

SF1=Tamper-proof Torx™-Head

Fasteners

Exam Light
EXLR
=Exam Light,
Switch Right Side
Mounted Facing
Unit.
EXLL=Exam Light,
Switch Left Side
Mounted Facing
Unit.

Voltage
120
=120V
277=277V
347=347V
UNV=120V

through
277V

Lamp Type
24" Nom.
Length

T8 Fluorescents
1/217
=(3) 17W

Lamps
1 Up, 2
Down

2/217=(4) 17W

Lamps
2 Up, 2
Down

T5HO
Fluorescents
1/224
=(3) 24W

Lamps
1 Up, 2
Down

2/224=(4) 24W

Lamps
2 Up, 2
Down

36" Nom.
Length

T8 Fluorescents
1/225
=(3) 25W

Lamps
1 Up, 2
Down

2/225=(4) 25W

Lamps
2 Up, 2
Down

T5HO
Fluorescents
1/239
=(3) 39W

Lamps
1 Up, 2
Down

2/239=(4) 39W

Lamps
2 Up, 2
Down

48" Nom.
Length

T8 Fluorescents
1/232
=(3) 32W

Lamps
1 Up, 2
Down

2/232=(4) 32W

Lamps
2 Up, 2
Down

T5HO
Fluorescents
1/254
=(3) 54W

Lamps
1 Up, 2
Down

2/254=(4) 54W

Lamps
2 Up, 2
Down

Accessories
(Order Separately)
MBC=Momentary button cord switch.

May be used with LVCP or LVCF
options to control lamps. (See
Switching Controls).

VRSD=TORX

®

-Head Vandal Resistant

Screwdriver

N o t e s : For additional options, consult your Cooper Lighting Representative.

Special Claims: When mounting, installer must verify fixture weight in selecting proper
anchoring; when not anchoring directly to stud. Refer to installation instructions.

The depicted luminaire is not rated for hazardous locations or adverse environments.
Illustrations and photographs depicted in this literature are representative examples only.
Consult the appropriate certified and licensed lighting engineering and installation
professionals for site-specific applications of products and codes.

Specifications and dimensions subject to change without notice.

1

Due to internal size limitations, some configurations and options are not available with
other options. Consult customer service.

2

120V only

Advertising